Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials

  • Review Article
  • Published:
Acta Diabetologica Aims and scope Submit manuscript

Abstract

Aims

Self-monitoring of blood glucose (SMBG) represented a major breakthrough in the treatment of type 1 diabetes. The aim of the present meta-analysis is to assess the effect of continues glucose monitoring (CGM) and flash glucose monitoring (FGM), on glycemic control in type 1 diabetes.

Materials and methods

The present analysis includes randomized clinical trials comparing CGM or FGM with SMBG, with a duration of at least 12 weeks, identified in Medline or clinicaltrials.gov. The principal endpoint was HbA1c at the end of the trial. A secondary endpoint was severe hypoglycemia. Mean and 95% confidence intervals for HbA1c and Mantel–Haenzel odds ratio [MH-OR] for severe hypoglycemia were calculated, using random effect models. A sensitivity analysis was performed using fixed effect models. In addition, the following secondary endpoints were explored, using the same methods: time in range, health-related quality of life, and treatment satisfaction. Separate analyses were performed for trials comparing CGM with SMBG, and those comparing CGM + CSII and SMBG + MDI and CGM-regulated insulin infusion system (CRIS) and CSII + SMBG.

Results

CGM was associated with a significantly lower HbA1c at endpoint in comparison with SMBG (− 0.24 [− 0.34, − 0.13]%); CGM was associated with a significantly lower risk of severe hypoglycemia than SMBG. Treatment satisfaction and quality of life were not measured, or not reported, in the majority of studies. FGM showed a significant reduction in the incidence of mild hypoglycemia and an increased treatment satisfaction, but no significant results are shown in HbA1c. CGM + CSII in comparison with SMBG + MDI was associated with a significant reduction in HbA1c. Only two trials with a duration of at least 12 weeks compared a CRIS with SMBG + CSII; HbA1c between the two treatment arms was not statistically significant (difference in means: − 0.23 [− 0.91; 0.46]%; p = 0.52).

Conclusion

GCM compared to SMBG has showed a reduction in HbA1c and severe hypoglycemia in patient with type 1 diabetes. The comparison between CGM + CSII and SMBG + MDI showed a large reduction in HbA1c; it is conceivable that the effects of CSII + CGM on glycemic control additives. The only comparison available between FGM and SMBG was conducted in patients in good control.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. Nathan DM, Genuth S, Lachin J et al (1993) The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 329(14):977–986. https://doi.org/10.1056/nejm199309303291401

    Article  CAS  PubMed  Google Scholar 

  2. Zimmerman BR (1994) Glycaemia control in diabetes mellitus. Towards the normal profile? Drugs 47(4):611–621. https://doi.org/10.2165/00003495-199447040-00005

    Article  CAS  PubMed  Google Scholar 

  3. Benkhadra K, Alahdab F, Tamhane S et al (2017) Real-time continuous glucose monitoring in type 1 diabetes: a systematic review and individual patient data meta-analysis. Clin Endocrinol (Oxf) 86(3):354–360. https://doi.org/10.1111/cen.13290

    Article  Google Scholar 

  4. Floyd B, Chandra P, Hall S et al (2012) Comparative analysis of the efficacy of continuous glucose monitoring and self-monitoring of blood glucose in type 1 diabetes mellitus. J Diabetes Sci Technol 6(5):1094–1102. https://doi.org/10.1177/193229681200600513

    Article  PubMed  PubMed Central  Google Scholar 

  5. Langendam M, Luijf YM, Hooft L, Devries JH, Mudde AH, Scholten RJ (2012) Continuous glucose monitoring systems for type 1 diabetes mellitus. Cochrane Database Syst Rev 1:Cd008101. https://doi.org/10.1002/14651858.cd008101.pub2

    Article  PubMed  Google Scholar 

  6. Leelarathna L, Wilmot EG (2018) Flash forward: a review of flash glucose monitoring. Diabet Med 35(4):472–482. https://doi.org/10.1111/dme.13584

    Article  CAS  PubMed  Google Scholar 

  7. Weinzimer SA, Tamborlane WV (2008) Sensor-augmented pump therapy in type 1 diabetes. Curr Opin Endocrinol Diabetes Obes 15(2):118–122. https://doi.org/10.1097/MED.0b013e3282f7960b

    Article  CAS  PubMed  Google Scholar 

  8. Weisman A, Bai JW, Cardinez M, Kramer CK, Perkins BA (2017) Effect of artificial pancreas systems on glycaemic control in patients with type 1 diabetes: a systematic review and meta-analysis of outpatient randomised controlled trials. Lancet Diabetes Endocrinol 5(7):501–512. https://doi.org/10.1016/s2213-8587(17)30167-5

    Article  CAS  PubMed  Google Scholar 

  9. Battelino T, Danne T, Bergenstal RM et al (2019) Clinical targets for continuous glucose monitoring data interpretation: recommendations from the international consensus on time in range. Diabetes Care 42(8):1593–1603. https://doi.org/10.2337/dci19-0028

    Article  PubMed  PubMed Central  Google Scholar 

  10. Soupal J, Parkin CG (2020) Response to Comment on Soupal et al. Glycemic outcomes in adults with T1D are impacted more by continuous glucose monitoring than by insulin delivery method: 3 years of follow-up from the COMISAIR study. Diabetes Care 43:37–43. https://doi.org/10.2337/dci20-0005(Diabetes Care 43(4): e54–e55)

    Article  CAS  PubMed  Google Scholar 

  11. Dicembrini I, Pala L, Caliri M et al (2020) Combined continuous glucose monitoring and subcutaneous insulin infusion versus self-monitoring of blood glucose with optimized multiple injections in people with type 1 diabetes: a randomized crossover trial. Diabetes Obes Metab. https://doi.org/10.1111/dom.14028

    Article  PubMed  Google Scholar 

  12. Liberati A, Altman DG, Tetzlaff J et al (2009) The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. BMJ 339:b2700. https://doi.org/10.1136/bmj.b2700

    Article  PubMed  PubMed Central  Google Scholar 

  13. Guyatt GH, Oxman AD, Vist GE et al (2008) GRADE: an emerging consensus on rating quality of evidence and strength of recommendations. BMJ 336(7650):924–926. https://doi.org/10.1136/bmj.39489.470347.AD

    Article  PubMed  PubMed Central  Google Scholar 

  14. Battelino T, Phillip M, Bratina N, Nimri R, Oskarsson P, Bolinder J (2011) Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes. Diabetes Care 34(4):795–800. https://doi.org/10.2337/dc10-1989

    Article  PubMed  PubMed Central  Google Scholar 

  15. Battelino T, Conget I, Olsen B et al (2012) The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: a randomised controlled trial. Diabetologia 55(12):3155–3162. https://doi.org/10.1007/s00125-012-2708-9

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  16. Beck RW, Riddlesworth TD, Ruedy KJ et al (2017) Effect of initiating use of an insulin pump in adults with type 1 diabetes using multiple daily insulin injections and continuous glucose monitoring (DIAMOND): a multicentre, randomised controlled trial. Lancet Diabetes Endocrinol 5(9):700–708. https://doi.org/10.1016/s2213-8587(17)30217-6

    Article  PubMed  Google Scholar 

  17. Deiss D, Bolinder J, Riveline JP et al (2006) Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring. Diabetes Care 29(12):2730–2732. https://doi.org/10.2337/dc06-1134

    Article  PubMed  Google Scholar 

  18. Heinemann L, Freckmann G, Ehrmann D et al (2018) Real-time continuous glucose monitoring in adults with type 1 diabetes and impaired hypoglycaemia awareness or severe hypoglycaemia treated with multiple daily insulin injections (HypoDE): a multicentre, randomised controlled trial. Lancet 391(10128):1367–1377. https://doi.org/10.1016/s0140-6736(18)30297-6

    Article  CAS  PubMed  Google Scholar 

  19. Hirsch IB, Abelseth J, Bode BW et al (2008) Sensor-augmented insulin pump therapy: results of the first randomized treat-to-target study. Diabetes Technol Ther 10(5):377–383. https://doi.org/10.1089/dia.2008.0068

    Article  CAS  PubMed  Google Scholar 

  20. Tamborlane WV, Beck RW, Bode BW et al (2008) Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med 359(14):1464–1476. https://doi.org/10.1056/NEJMoa0805017

    Article  PubMed  Google Scholar 

  21. Lagarde WH, Barrows FP, Davenport ML, Kang M, Guess HA, Calikoglu AS (2006) Continuous subcutaneous glucose monitoring in children with type 1 diabetes mellitus: a single-blind, randomized, controlled trial. Pediatr Diabetes 7(3):159–164. https://doi.org/10.1111/j.1399-543X.2006.00162.x

    Article  PubMed  Google Scholar 

  22. Lind M, Polonsky W, Hirsch IB et al (2017) Continuous glucose monitoring vs conventional therapy for glycemic control in adults with type 1 diabetes treated with multiple daily insulin injections: the GOLD randomized clinical trial. JAMA 317(4):379–387. https://doi.org/10.1001/jama.2016.19976

    Article  CAS  PubMed  Google Scholar 

  23. Mauras N, Beck R, **ng D et al (2012) A randomized clinical trial to assess the efficacy and safety of real-time continuous glucose monitoring in the management of type 1 diabetes in young children aged 4 to < 10 years. Diabetes Care 35(2):204–210. https://doi.org/10.2337/dc11-1746

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  24. O’Connell MA, Donath S, O’Neal DN et al (2009) Glycaemic impact of patient-led use of sensor-guided pump therapy in type 1 diabetes: a randomised controlled trial. Diabetologia 52(7):1250–1257. https://doi.org/10.1007/s00125-009-1365-0

    Article  CAS  PubMed  Google Scholar 

  25. Olivier P, Lawson ML, Huot C, Richardson C, Nakhla M, Romain J (2014) Lessons learned from a pilot RCT of simultaneous versus delayed initiation of continuous glucose monitoring in children and adolescents with type 1 diabetes starting insulin pump therapy. J Diabetes Sci Technol 8(3):523–528. https://doi.org/10.1177/1932296814524855

    Article  PubMed  PubMed Central  Google Scholar 

  26. Raccah D, Sulmont V, Reznik Y et al (2009) Incremental value of continuous glucose monitoring when starting pump therapy in patients with poorly controlled type 1 diabetes: the RealTrend study. Diabetes Care 32(12):2245–2250. https://doi.org/10.2337/dc09-0750

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  27. Riveline JP, Schaepelynck P, Chaillous L et al (2012) Assessment of patient-led or physician-driven continuous glucose monitoring in patients with poorly controlled type 1 diabetes using basal-bolus insulin regimens: a 1-year multicenter study. Diabetes Care 35(5):965–971. https://doi.org/10.2337/dc11-2021

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  28. Sequeira PA, Montoya L, Ruelas V et al (2013) Continuous glucose monitoring pilot in low-income type 1 diabetes patients. Diabetes Technol Ther 15(10):855–858. https://doi.org/10.1089/dia.2013.0072

    Article  PubMed  PubMed Central  Google Scholar 

  29. Tumminia A, Crimi S, Sciacca L et al (2015) Efficacy of real-time continuous glucose monitoring on glycaemic control and glucose variability in type 1 diabetic patients treated with either insulin pumps or multiple insulin injection therapy: a randomized controlled crossover trial. Diabetes Metab Res Rev 31(1):61–68. https://doi.org/10.1002/dmrr.2557

    Article  CAS  PubMed  Google Scholar 

  30. New JP, Ajjan R, Pfeiffer AF, Freckmann G (2015) Continuous glucose monitoring in people with diabetes: the randomized controlled Glucose Level Awareness in Diabetes Study (GLADIS). Diabet Med 32(5):609–617. https://doi.org/10.1111/dme.12713

    Article  CAS  PubMed  Google Scholar 

  31. van Beers CA, DeVries JH, Kleijer SJ et al (2016) Continuous glucose monitoring for patients with type 1 diabetes and impaired awareness of hypoglycaemia (IN CONTROL): a randomised, open-label, crossover trial. Lancet Diabetes Endocrinol 4(11):893–902. https://doi.org/10.1016/s2213-8587(16)30193-0

    Article  PubMed  Google Scholar 

  32. Olafsdottir AF, Polonsky W, Bolinder J et al (2018) A randomized clinical trial of the effect of continuous glucose monitoring on nocturnal hypoglycemia, daytime hypoglycemia, glycemic variability, and hypoglycemia confidence in persons with type 1 diabetes treated with multiple daily insulin injections (GOLD-3). Diabetes Technol Ther 20(4):274–284. https://doi.org/10.1089/dia.2017.0363

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  33. Guilmin-Crepon S, Carel JC, Schroedt J et al (2019) Is there an optimal strategy for real-time continuous glucose monitoring in pediatrics? A 12-month French multi-center, prospective, controlled randomized trial (Start-In!). Pediatr Diabetes 20(3):304–313. https://doi.org/10.1111/pedi.12820

    Article  CAS  PubMed  Google Scholar 

  34. Kordonouri O, Hartmann R, Pankowska E et al (2012) Sensor augmented pump therapy from onset of type 1 diabetes: late follow-up results of the pediatric onset study. Pediatr Diabetes 13(7):515–518. https://doi.org/10.1111/j.1399-5448.2012.00863.x

    Article  CAS  PubMed  Google Scholar 

  35. Bolinder J, Antuna R, Geelhoed-Duijvestijn P, Kroger J, Weitgasser R (2016) Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial. Lancet 388(10057):2254–2263. https://doi.org/10.1016/s0140-6736(16)31535-5

    Article  PubMed  Google Scholar 

  36. Hermanides J, Norgaard K, Bruttomesso D et al (2011) Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial. Diabet Med 28(10):1158–1167. https://doi.org/10.1111/j.1464-5491.2011.03256.x

    Article  CAS  PubMed  Google Scholar 

  37. Peyrot M, Rubin RR (2009) Patient-reported outcomes for an integrated real-time continuous glucose monitoring/insulin pump system. Diabetes Technol Ther 11(1):57–62. https://doi.org/10.1089/dia.2008.0002

    Article  CAS  PubMed  Google Scholar 

  38. Bergenstal RM, Tamborlane WV, Ahmann A et al (2010) Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med 363(4):311–320. https://doi.org/10.1056/NEJMoa1002853

    Article  CAS  PubMed  Google Scholar 

  39. Ly TT, Nicholas JA, Retterath A, Lim EM, Davis EA, Jones TW (2013) Effect of sensor-augmented insulin pump therapy and automated insulin suspension vs standard insulin pump therapy on hypoglycemia in patients with type 1 diabetes: a randomized clinical trial. JAMA 310(12):1240–1247. https://doi.org/10.1001/jama.2013.277818

    Article  CAS  PubMed  Google Scholar 

  40. Education effectiveness for type 1 diabetes mellitus on insulin pump therapy (EASEDIAP) [article online] (2016). https://clinicaltrials.gov/ct2/show/NCT02423993. Accessed 07 Oct 2019

  41. Babar GS, Ali O, Parton EA, Hoffmann RG, Alemzadeh R (2009) Factors associated with adherence to continuous subcutaneous insulin infusion in pediatric diabetes. Diabetes Technol Ther 11(3):131–137. https://doi.org/10.1089/dia.2008.0042

    Article  CAS  PubMed  Google Scholar 

  42. Pala L, Dicembrini I, Mannucci E (2019) Continuous subcutaneous insulin infusion vs modern multiple injection regimens in type 1 diabetes: an updated meta-analysis of randomized clinical trials. Acta Diabetol 56(9):973–980. https://doi.org/10.1007/s00592-019-01326-5

    Article  CAS  PubMed  Google Scholar 

  43. Brown S, Raghinaru D, Emory E, Kovatchev B (2018) First look at control-IQ: a new-generation automated insulin delivery system. Diabetes Care 41(12):2634–2636. https://doi.org/10.2337/dc18-1249

    Article  PubMed  PubMed Central  Google Scholar 

  44. Zhong A, Choudhary P, McMahon C et al (2016) Effectiveness of automated insulin management features of the MiniMed((R)) 640G sensor-augmented insulin pump. Diabetes Technol Ther 18(10):657–663. https://doi.org/10.1089/dia.2016.0216

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  45. Aleppo G, Webb KM (2018) Integrated insulin pump and continuous glucose monitoring technology in diabetes care today: a perspective of real-life experience with the MiniMed() 670G hybrid closed-loop system. Endocr Pract 24(7):684–692. https://doi.org/10.4158/ep-2018-0097

    Article  PubMed  Google Scholar 

  46. Mancini G, Berioli MG, Santi E et al (2018) Flash glucose monitoring: a review of the literature with a special focus on type 1 diabetes. Nutrients. https://doi.org/10.3390/nu10080992

    Article  PubMed  PubMed Central  Google Scholar 

  47. Paris I, Henry C, Pirard F, Gerard AC, Colin IM (2018) The new FreeStyle libre flash glucose monitoring system improves the glycaemic control in a cohort of people with type 1 diabetes followed in real-life conditions over a period of one year. Endocrinol Diabetes Metab 1(3):e00023. https://doi.org/10.1002/edm2.23

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  48. Haak T, Hanaire H, Ajjan R, Hermanns N, Riveline JP, Rayman G (2017) Flash glucose-sensing technology as a replacement for blood glucose monitoring for the management of insulin-treated type 2 diabetes: a multicenter, open-label randomized controlled trial. Diabetes Ther 8(1):55–73. https://doi.org/10.1007/s13300-016-0223-6

    Article  CAS  PubMed  Google Scholar 

  49. Dicembrini I, Mannucci E, Monami M, Pala L (2019) Impact of technology on glycaemic control in type 2 diabetes: a meta-analysis of randomized trials on continuous glucose monitoring and continuous subcutaneous insulin infusion. Diabetes Obes Metab 21(12):2619–2625. https://doi.org/10.1111/dom.13845

    Article  CAS  PubMed  Google Scholar 

  50. Boscari F, Galasso S, Facchinetti A et al (2018) FreeStyle Libre and Dexcom G4 platinum sensors: accuracy comparisons during two weeks of home use and use during experimentally induced glucose excursions. Nutr Metab Cardiovasc Dis 28(2):180–186. https://doi.org/10.1016/j.numecd.2017.10.023

    Article  CAS  PubMed  Google Scholar 

  51. Reddy M, Jugnee N, El Laboudi A, Spanudakis E, Anantharaja S, Oliver N (2018) A randomized controlled pilot study of continuous glucose monitoring and flash glucose monitoring in people with Type 1 diabetes and impaired awareness of hypoglycaemia. Diabet Med 35(4):483–490. https://doi.org/10.1111/dme.13561

    Article  CAS  PubMed  Google Scholar 

  52. Foster NC, Beck RW, Miller KM et al (2019) State of type 1 diabetes management and outcomes from the T1D exchange in 2016–2018. Diabetes Technol Ther 21(2):66–72. https://doi.org/10.1089/dia.2018.0384

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  53. Wan W, Skandari MR, Minc A et al (2018) Cost-effectiveness of initiating an insulin pump in T1D adults using continuous glucose monitoring compared with multiple daily insulin injections: the DIAMOND randomized trial. Med Decis Mak 38(8):942–953. https://doi.org/10.1177/0272989x18803109

    Article  Google Scholar 

Download references

Funding

This research was performed independently of any funding, as part of the institutional activity of the investigators. The corresponding author had full access to all the data in the study and had final responsibility for the decision to submit for publication.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to L. Pala.

Ethics declarations

Conflict of interest

All authors declare no conflict of interest.

Ethical approval

This article does not contain any studies with human or animal performed by any authors.

Informed consent

Informed consent is not required.

Additional information

Managed by Antonio Secchi.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary material 1 (DOCX 487 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Dicembrini, I., Cosentino, C., Monami, M. et al. Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials. Acta Diabetol 58, 401–410 (2021). https://doi.org/10.1007/s00592-020-01589-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00592-020-01589-3

Keywords

Navigation