Abstract
Purpose
To analyze clinical, radiographic and patient-reported outcomes of distal metaphyseal femoral nonunions treated with fixed-angle plates and screws.
Methods
All patients presenting with a distal metaphyseal femoral fracture nonunion repaired with fixed-angle plating from one urban level 1 trauma center and an orthopedic specialty hospital were identified. Baseline demographic, injury information, and outcomes (healing rates, Short Musculoskeletal Function Assessment, range of motion, and post-operative pain levels) at 12 months following nonunion repair were collected. Outcomes were evaluated between patients fixed with a blade plate and with a locking plate.
Results
Of these 31 patients, 27 (87.1%) healed after their index nonunion surgery, 2 (6.5%) healed after one reoperation, 1 (3.2%) healed after 2 reoperations, and 1 (3.2%) had a persistent nonunion but did not want further treatment. At one-year follow-up, the group demonstrated a significant improvement in functional recovery with a mean difference of 14.5 points (p = 0.007) when compared to status before fixed-angle fixation of the nonunion. There was also a significant change in patient-reported pain levels using the VAS scale with a mean difference of 2.0 points (p = 0.009). At one-year follow-up, 11 (39.3%) had full knee range of motion (0–130), 11 (39.3%) had flexion greater than 90 and less than 120°, and 6 (21.4%) had range of motion less than 90°.
Conclusion
Patients who undergo fixed angle plating and autogenous bone grafting for distal femoral metapyseal nonunions demonstrate improved functional outcomes and VAS pain score at one year follow up.
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00590-022-03366-0/MediaObjects/590_2022_3366_Fig1_HTML.jpg)
Similar content being viewed by others
References
Brinker MR, O’Connor DP (2016) The biological basis for nonunions. JBJS Rev. https://doi.org/10.2106/JBJS.RVW.15.00078
Niikura T, Lee SY, Sakai Y, Nishida K, Kuroda R, Kurosaka M (2014) Causative factors of fracture nonunion: the proportions of mechanical, biological, patient-dependent, and patient-independent factors. J Orthop Sci 19(1):120–124. https://doi.org/10.1007/s00776-013-0472-4
Zura R, **ong Z, Einhorn T, Watson JT, Ostrum RF, Prayson MJ et al (2016) Epidemiology of fracture nonunion in 18 human bones. JAMA Surg 151(11):e162775. https://doi.org/10.1001/jamasurg.2016.2775
Egol KA, Bechtel C, Spitzer AB, Rybak L, Walsh M, Davidovitch R (2012) Treatment of long bone nonunions: factors affecting healing. Bull NYU Hosp Jt Dis 70(4):224–231
Egol KA, Koval KJ, Zuckerman J (2015) Handbook of fractures, 5th edn. Wolters Kluwer Health, New York
Harder Y, Martinet O, Barraud GE, Cordey J, Regazzoni P (1999) The mechanics of internal fixation of fractures of the distal femur: a comparison of the condylar screw (DCS) with the condylar plate (CP). Injury 30(Suppl 1):A31–A39. https://doi.org/10.1016/s0020-1383(99)00124-2
Hake ME, Davis ME, Perdue AM, Goulet JA (2019) Modern implant options for the treatment of distal femur fractures. J Am Acad Orthop Surg 27(19):e867–e875. https://doi.org/10.5435/JAAOS-D-17-00706
Wagner M (2003) General principles for the clinical use of the LCP. Injury 34(Suppl 2):B31-42. https://doi.org/10.1016/j.injury.2003.09.023
Higgins TF, Pittman G, Hines J, Bachus KN (2007) Biomechanical analysis of distal femur fracture fixation: fixed-angle screw-plate construct versus condylar blade plate. J Orthop Trauma 21(1):43–46. https://doi.org/10.1097/BOT.0b013e31802bb372
Strauss EJ, Schwarzkopf R, Kummer F, Egol KA (2008) The current status of locked plating: the good, the bad, and the ugly. J Orthop Trauma 22(7):479–486. https://doi.org/10.1097/BOT.0b013e31817996d6
Jaakkola JI, Lundy DW, Moore T, Jones B, Ganey TM, Hutton WC (2002) Supracondylar femur fracture fixation: mechanical comparison of the 95 degrees condylar side plate and screw versus 95 degrees angled blade plate. Acta Orthop Scand 73(1):72–76. https://doi.org/10.1080/000164702317281440
Weber BG, Cech O (1976) Pseudarthrosis: pathophysiology, biomechanics, therapy, results. Grune & Stratton, New York
Orbay J, Badia A, Khoury RK, Gonzalez E, Indriago I (2004) Volar fixed-angle fixation of distal radius fractures: the DVR plate. Tech Hand Up Extrem Surg 8(3):142–148. https://doi.org/10.1097/01.bth.0000126570.82826.0a
Cronier P, Pietu G, Dujardin C, Bigorre N, Ducellier F, Gerard R (2010) The concept of locking plates. Orthop Traumatol Surg Res. https://doi.org/10.1016/j.otsr.2010.03.008
Vallier HA, Immler W (2012) Comparison of the 95-degree angled blade plate and the locking condylar plate for the treatment of distal femoral fractures. J Orthop Trauma 26(6):327–332. https://doi.org/10.1097/BOT.0b013e318234d460
Button G, Wolinsky P, Hak D (2004) Failure of less invasive stabilization system plates in the distal femur: a report of four cases. J Orthop Trauma 18(8):565–570. https://doi.org/10.1097/00005131-200409000-00015
Ebraheim NA, Martin A, Sochacki KR, Liu J (2013) Nonunion of distal femoral fractures: a systematic review. Orthop Surg 5(1):46–50. https://doi.org/10.1111/os.12017
Rodriguez EK, Zurakowski D, Herder L, Hall A, Walley KC, Weaver MJ et al (2016) Mechanical construct characteristics predisposing to non-union after locked lateral plating of distal femur fractures. J Orthop Trauma 30(8):403–408. https://doi.org/10.1097/BOT.0000000000000593
Ricci WM, Streubel PN, Morshed S, Collinge CA, Nork SE, Gardner MJ (2014) Risk factors for failure of locked plate fixation of distal femur fractures: an analysis of 335 cases. J Orthop Trauma 28(2):83–89. https://doi.org/10.1097/BOT.0b013e31829e6dd0
Monroy A, Urruela A, Singh P, Tornetta P 3rd, Egol KA (2014) Distal femur nonunion patients can expect good outcomes. J Knee Surg 27(1):83–87. https://doi.org/10.1055/s-0033-1349402
Shulman BS, Patsalos-Fox B, Lopez N, Konda SR, Tejwani NC, Egol KA (2014) Do elderly patients fare worse following operative treatment of distal femur fractures using modern techniques? Geriatr Orthop Surg Rehabil 5(1):27–30. https://doi.org/10.1177/2151458514525041
Reed LK, Mormino MA (2008) Distal tibia nonunions. Foot Ankle Clin 13(4):725–735. https://doi.org/10.1016/j.fcl.2008.09.001
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
All authors declare that they have no conflicts of interest related to the contents of this manuscript. Authorship has been granted only to those individuals who have contributed substantially to the research or manuscript. No sources of funding have been granted for this study.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Springer Nature or its licensor holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Landes, E.K., Konda, S.R., Leucht, P. et al. Fixed-angle plate fixation and autogenous iliac crest graft for repair of distal metaphyseal femoral nonunion. Eur J Orthop Surg Traumatol 33, 1835–1839 (2023). https://doi.org/10.1007/s00590-022-03366-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00590-022-03366-0