Abstract
The aim of this study was presentation of a whole-body MRI technique with a moving table as a screening tool for bone metastases in patients with breast cancer. Twenty-two patients with breast carcinoma underwent both a planar whole-body bone scintigraphy and whole-body MRI at 1.5 T. The MRI images were acquired with a moving table at six different anatomical positions within a measurement time of 20 min. Coronal images were acquired using a short-tau inversion recovery sequence, accomplished by an axial T2-weighted turbo-spin-echo sequence through the head, and a T1-weighted opposed-phase sagittal 2D fast low-angle shot sequence covering the whole spine. The MRI findings indicating bone metastases were compared with findings from bone scintigraphy. Metastatic lesions were confirmed by follow-up examinations over 1 year. Twelve patients showed bone metastases. Whole-body MRI was superior to bone scintigraphy in predicting lesion origin with a sensitivity of 92% (bone scintigraphy 83%), a specificity of 90% (scintigraphy 80%) and an accuracy of 91% (scintigraphy 82%). The MRI showed additional findings such as metastases of the lung and liver. Whole-body MRI with moving table technique may be an effective method of total body screening for bone in selected patients with breast carcinoma and a high risk of distant metastases, although with the higher costs of MRI bone scintigraphy must still be considered as the first method for screening patients with breast cancer.
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00330-003-1968-7/MediaObjects/s00330-003-1968-7flb1a-b.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00330-003-1968-7/MediaObjects/s00330-003-1968-7fhb2a-b.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00330-003-1968-7/MediaObjects/s00330-003-1968-7fhb3a-b.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00330-003-1968-7/MediaObjects/s00330-003-1968-7fhb4a-c.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00330-003-1968-7/MediaObjects/s00330-003-1968-7fhb5a-b.jpg)
Similar content being viewed by others
References
Flickinger FW, Sanal SM (1994) Bone marrow MRI: techniques and accuracy for detecting breast cancer metastases. J Magn Reson Imaging 12:829–835
Söderlund V (1996) Radiological diagnosis of skeletal metastases. Eur Radiol 6:587–595
Layer G, Jarosch K (1992) Bone marrow MRI for evaluation of metastases of solid tumors. Radiologe 32:502–508
Walker RE, Eustace SJ (2001) Whole-body magnetic resonance imaging: techniques, clinical indications, and future applications. Semin Musculoskelet Radiol 5:5–201
Daldrup-Link HE, Franzius C, Link TM et al. (2001) Whole-body MR imaging for detection of bone metastases in children and young adults: comparison with skeletal scintigraphy and FDG PET. AJR 177:229–236
Walker RE, Kessar P, Blanchard R et al. (2000) Turbo-STIR magnetic resonance imaging as a whole-body screening tool for metastases in patients with breast carcinoma: preliminary clinical experience. J Magn Reson Imaging 11:343–350
Steinborn M, Tiling R, Heuck A, Brügel M, Stäbler A, Reiser M (2000) Diagnosis of bone marrow metastases with MRI. Radiologe 40:826–834
Steinborn M, Heuck A, Tiling R, Bruegel M, Gauger L, Reiser M (1999) Whole-body bone MRI in patients with metastatic disease to the skeletal system. J Comput Assist Tomogr 23:123–129
Horvath LJ, Burtness BA, McCarthy S, Johnson KM (1999) Total-body echo-planar MR imaging in the staging of breast cancer: comparison with conventional methods; early experience. Radiology 211:119–128
Chan Y, Chan K, Lam W, Metreweli C (1997) Comparison of whole-body MRI and radioisotope bone scintigram for skeletal metastases detection. Clin Med J 110:485–489
Tamada T, Nagai K, Iizuka M et al. (2000) Comparison of a whole-body MR imaging and bone scintigraphy in the detection of bone mteastases from breast cancer. Nippon Igaku Hoshasen Gakkai Zasshi 60:249–254
Barkhausen J, Quick HH, Lauenstein T et al. (2001) Whole-body MR imaging in 30 s with real-time true FISP and a continuously rolling table platform: feasibility study. Radiology 220:252–256
Johnson KMR, Leavitt GD, Kayser HWM (1997) Total-body MR imaging in as little as 18 s. Radiology 202:262–267
Lauenstein TC, Freudenberg LS, Goehde SC et al. (2002) Whole-body MRI using a rolling table platform for the detection of bone metastases. Eur Radiol 12:2091–2099
Lauenstein TC, Goehde SC, Herborn CU et al. (2002) Three-dimensional volumetric interpolated breath-hold MR imaging for whole-body tumor staging in less than 15 min: a feasibility study. AJR 179:445–449
Vanel D, Bittoun J, Tardivon A (1998) MRI of bone metastases. Eur Radiol 8:1345–1351
Vahlensieck M, Schmidt HM (2000) Normal bone marrow and its variations in MRI. Radiologe 40:688–693
Seiderer M, Wagner H, Stäbler A, Fink U (1994) MRI of focal lesions of red bone marrow: optimisation of acquisition parameters for GE and SE sequences. RoFo 160:453–458
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Engelhard, K., Hollenbach, H.P., Wohlfart, K. et al. Comparison of whole-body MRI with automatic moving table technique and bone scintigraphy for screening for bone metastases in patients with breast cancer. Eur Radiol 14, 99–105 (2004). https://doi.org/10.1007/s00330-003-1968-7
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00330-003-1968-7