Abstract
An in-situ microanalysis of Pb isotopic compositions in sulfide minerals is carried out by using femtosecond laser-ablation multi-collector inductively coupled plasma mass spectrometry (fsLA-MC-ICP-MS). High-temperature-activated carbon was used to filter Hg contained in the carrier gas, which reduced the Hg background signal by 48% and also lowered the detection limit of the analysis. Fractionation and mass discrimination effects existing in the ICP-MS analytical processes were corrected using an internal reference Tl in conjunction with an external reference NIST SRM 610. The proposed method was used to analyze the Pb isotopic compositions of chalcopyrite, pyrite, and sphalerite from the Dulong Sn-Zn-In polymetallic ore district. The results showed that in this ore district, the sulfide minerals and different grains of the same sulfide mineral show a large variation in Pb content up to 1000-fold. The studied pyrites show relatively higher Pb contents and homogeneous Pb isotopic compositions, whereas the sphalerites have low Pb contents but most variable Pb isotopic compositions. It is suggested that the large variation of Pb isotopic composition may reflect a late hydrothermal superimposition on the primary sulfide formation. In addition, radiogenic Pb accumulated by radioactive decay of trace amounts of U over time in the host minerals may also be one of the causes for the large variation range of Pb content and Pb isotopic composition of those low-Pb sphalerites. Chalcopyrite and sphalerite grains with Pb content greater than 10 ppm presented a consistent Pb isotopic distribution, whereas all the sulfide grains with Pb content greater than 100 ppm had consistent Pb isotopic composition within 2s measurement uncertainties. The in-situ analysis of Pb isotopic composition agreed well with the results obtained by conventional chemical methods within 2s measurement uncertainties, indicating that the data obtained by fsLA-MC-ICP-MS are reliable. Additionally, this study indicates that the Pb isotopic composition could truthfully record the source of ore-forming minerals only for sulfide minerals with high Pb content. On the contrary, the Pb isotopic composition of low-Pb sulfide minerals may be affected by trace amounts of U in the host minerals that may lead to a highly radiogenic Pb isotope ratio. Alternatively, it is also possible that late fluid metasomatic overprinting may alter the Pb isotopic compositions.
Similar content being viewed by others
References
Baker J, Peate D, Waight T, et al. 2004. Pb isotopic analysis of standards and samples using a 207Pb-204Pb double spike and thallium to correct for mass bias with a double-focusing MC-ICP-MS. Chem Geol, 211: 275–303
Belshaw N S, Freedman P A, O’Nions R K, et al. 1998. A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes. Int J Mass Spectrosc, 181: 51–58
Chang X Y, Shu B Q, Ju R. 2000. Lead isotope geochemical profile and depth prediction of concealed ore: A Case Study of Copper of Yunnan **pinlong River. Sci Sin Terrae, 30: 33–39
Chang X, Zhu B. 1997. Application of lead isotopes to geochemical exploration and evaluation. Bull Mineral Petrol Geochem, 16: 245–249
Chang X Y, Zhu B Q. 2002. Isotope Geochemistry of the Dongchuan copper deposit, Yuannan, SW China: Stratigraphic chronology and application of lead isotopes in geochemical exploration. Chin J Geochem, 21: 65–72
Chang X Y, Zhu B Q, Yu S J, et al. 2003. Application of lead isotopes to geochemical exploration of gold deposits in Baoban, Hainan Province, China. Chin J Geochem, 22: 244–252
Chen K Y, Yuan H L, Bao Z A, et al. 2014. Precise and accurate in situ determination of lead isotope ratios in NIST, USGS, MPI-DING and CGSG glass reference materials using Femtosecond Laser Ablation MC-ICP-MS. Geostand Geoanal Res, 38: 5–21
Chen Y Y. 2013. The Sn-Zn multimetallic deposit of Western Manjiazhai ore block of Dulong Sn Deposit, Yunnan. Yunnan Geol, 32: 296–299
Darling J R, Storey C D, Hawkesworth C J, et al. 2012. In-situ Pb isotope analysis of Fe-Ni-Cu sulphides by laser ablation multi-collector ICP-MS: New insights into ore formation in the Sudbury impact melt sheet. Geochim Cosmochim Ac, 99: 1–17
Ding Q F, Jiang S Y, Sun F Y, et al. 2013. Origin of the Dachang gold deposit, NW China: constraints from H, O, S, and Pb isotope data. Int Geol Rev, 55: 1885–1901
Hoskin P W O, Wysoczanski R J. 1998. In situ accurate and precise lead isotopic analysis of ultra-small analyte volumes (10-(16)m(3)) of solid inorganic samples by high mass resolution secondary ion mass spectrometry. J Anal Atom Spectrom, 13: 597–601
Hou M L, Jiang S Y, Jiang Y H, et al. 2006. S-Pb isotope geochemistry and Rb-Sr geochronology of the Penglai gold field in the eastern Shangdong Province. Acta Petrol Sin, 20: 2525–2533
Jiang S Y, Yang T, Li L, et al. 2006. Lead and sulfur isotopic compositions of sulfides from the TAG hydrothermal field, Mid-Atlantic Ridge. Acta Petrol Sin, 22: 2597–2602
Liu Y. 1998. Geochemistry of Dulong superlarge Tin-zinc-polymetallic deposit, Yunnan. Bull Mineral Petrol Geochem, 17: 22–24
Malherbe J, Claverie F, Alvarez A, et al. 2013. Elemental analyses of soil and sediment fused with lithium borate using isotope dilution laser ablation-inductively coupled plasma-mass spectrometry. Anal Chim Acta, 793: 72–78
Mathez E A, Waight T E. 2003. Lead isotopic disequilibrium between sulfide and plagioclase in the Bushveld Complex and the chemical evolution of large layered intrusions. Geochim Cosmochim Acta, 67: 1875–1888
Mil-Homens M, Blum J, Canário J, et al. 2013. Tracing anthropogenic Hg and Pb input using stable Hg and Pb isotope ratios in sediments of the central Portuguese Margin. Chem Geol, 336: 62–71
Novak M, Pacherova P, Erbanova L, et al. 2012. Using S and Pb isotope ratios to trace leaching of toxic substances from an acid-impacted industrial-waste landfill (Pozdatky, Czech Republic). J Hazard Mater, 235–236: 54–61
Paul A, Jung S, Romer R L, et al. 2014. Petrogenesis of synorogenic high-temperature leucogranites (Damara orogen, Namibia): Constraints from U-Pb monazite ages and Nd, Sr and Pb isotopes. Gondwana Res, 25: 1614–1626
Pettke T, Oberli F, Audétat A, et al. 2012. Recent developments in element concentration and isotope ratio analysis of individual fluid inclusions by laser ablation single and multiple collector ICP-MS. Ore Geol Rev, 44: 10–38
Rehkämper M, Mezger K. 2000. Investigation of matrix effects for Pb isotope ratio measurements by multiple collector ICPMS: Verification and application of optimised analytical protocols. J Anal Atom Spectrom, 15: 1451–1460
Sjåstad K E, Andersen T, Simonsen S L. 2013. Application of laser ablation inductively coupled plasma multicollector mass spectometry in determination of lead isotope ratios in common glass for forensic purposes. Spectrochim Acta B, 89: 84–92
Souders A K, Sylvester P J. 2010. Accuracy and precision of non-matrix-matched calibration for lead isotope ratio measurements of lead-poor minerals by LA-MC-ICPMS. J Anal Atom Spectrom, 25: 975–988
Townsend A, Yu Z, McGoldrick P, et al. 1998. Precise lead isotope ratios in Australian galena samples by high resolution inductively coupled plasma mass spectrometry. J Anal Atom Spectrom, 13: 809–813
Walraven N, van Gaans P F M, van der Veer G, et al. 2013a. Lithologically inherited variation in Pb isotope ratios in sedimentary soils in The Netherlands. Appl Geochem, 37: 228–241
Walraven N, van Gaans P F M, van der Veer G, et al. 2013b. Tracing diffuse anthropogenic Pb sources in rural soils by means of Pb isotope analysis. Appl Geochem, 37: 242–257
Walraven N, van Os B J H, Klaver G T, et al. 2014a. The lead (Pb) isotope signature, behaviour and fate of traffic-related lead pollution in roadside soils in The Netherlands. Sci Total Environ, 472: 888–900
Walraven N, van Os B J H, Klaver G T, et al. 2014b. Reconstruction of historical atmospheric Pb using Dutch urban lake sediments: A Pb isotope study. Sci Total Environ, 484: 185–195
Wang C, Wang J, Yang Z, et al. 2013. Characteristics of lead geochemistry and the mobility of Pb isotopes in the system of pedogenic rock-pedosphere-irrigated riverwater-cereal-atmosphere from the Yangtze River delta region, China. Chemosphere, 93: 1927–1935
Westgate J A, Pearce N J G, Perkins W T, et al. 2011. Lead isotope ratios of volcanic glass by laser ablation inductively-coupled plasma mass spectrometry: Application to Miocene tephra beds in Montana, USA and adjacent areas. Quatern Int, 246: 82–96
Woodhead J, Hergt J, Meffre S, et al. 2009. In situ Pb-isotope analysis of pyrite by laser ablation (multi-collector and quadrupole) ICPMS. Chem Geol, 262: 344–354
Yuan H L, Chen K Y, Bao Z A, et al. 2013. Determination of lead isotope compositions of geological samples using femtosecond laser ablation MC-ICPMS. Chin Sci Bull, 58: 3914–3921
Zhang J R, Wen H J. 2012. Sulfur and lead isotope compositions and tracing of copper deposits on the western border of the Lan** Basin, Yunnan Province. Geochimica, 41: 166–180
Zhao K D, Jiang S Y, Ni P, et al. 2007. Sulfur, lead and helium isotopic compositions of sulfide minerals from the Dachang Sn-polymetallic ore district in South China: Implication for ore genesis. Miner Petrol, 89: 251–273
Zhu B Q. 1998. Theory and Applications of Isotope Systematics in Geosciences: Evolution of Continental Crust and Mantle in China (in Chinese). Bei**g: Science Press
Zhu B. 1993. Tri-Dimension spacial topological diagrams of ore lead isotopes and their application to the division of geochemical proviences and mineralizations. Geochimica, 22: 209–216
Zhu L, Guo L, Gao Z, et al. 2010. Source and distribution of lead in the surface sediments from the South China Sea as derived from Pb isotopes. Mar Pollut Bull, 60: 2144–2153
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Yuan, H., Yin, C., Liu, X. et al. High precision in-situ Pb isotopic analysis of sulfide minerals by femtosecond laser ablation multi-collector inductively coupled plasma mass spectrometry. Sci. China Earth Sci. 58, 1713–1721 (2015). https://doi.org/10.1007/s11430-015-5095-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11430-015-5095-5