Abstract
Iron overload is a common clinical problem resulting from hereditary hemochromatosis or secondary hemosiderosis (mainly associated with transfusion therapy), being also associated with chronic liver diseases and metabolic disorders. Excess of iron accumulates in organs like the liver, pancreas and heart. Without treatment, patients with iron overload disorders will develop liver cirrhosis, diabetes and cardiomyopathy. Iron quantification is therefore crucial not only for diagnosis of iron overload but also to monitor iron-reducing therapies. Liver iron concentration is considered the surrogate marker of total body iron stores. Because liver biopsy is invasive and prone to high variability and sampling bias, MR imaging has emerged as a non-invasive method and gained wide acceptance, now being considered the standard of care for assessing iron overload. Nevertheless, there are different MR techniques for iron quantification and there is still no consensus about the best technique or postprocessing tool for hepatic iron quantification, with the choice of imaging technique depending mainly on the local expertise as well on the available equipment and software. Because different methods should not be used interchangeably, it is important to choose one method and use the same one when following up patients over time.
Similar content being viewed by others
References
Steinbicker A, Muckenthaler M (2013) Out of Balance — Systemic Iron Homeostasis in Iron-Related Disorders. Nutrients 5:3034–3061. https://doi.org/10.3390/nu5083034
Pietrangelo A (2016) Mechanisms of iron hepatotoxicity. J Hepatol. https://doi.org/10.1016/j.jhep.2016.01.037
Ganz T (2008) Iron Homeostasis: Fitting the Puzzle Pieces Together. Cell Metabolism 7:288–290. https://doi.org/10.1016/j.cmet.2008.03.008
European Association for the Study of the Liver (2010) EASL clinical practice guidelines for HFE hemochromatosis. J Hepatol 53:3–22. https://doi.org/10.1016/j.jhep.2010.03.001
Zoller H, Henninger B (2016) Pathogenesis, Diagnosis and Treatment of Hemochromatosis. Dig Dis 34:364–373. https://doi.org/10.1159/000444549
[6] Pietrangelo A (2015) Genetics, Genetic Testing, and Management of Hemochromatosis: 15 Years Since Hepcidin. Gastroenterology 149:1240–1251.e4. https://doi.org/10.1053/j.gastro.2015.06.045
Pietrangelo A, Corradini E, Ferrara F, Vegetti A, De Jong G, Luca Abbati G, Paolo Arcuri P, Martinelli S, Cerofolini E (2006) Magnetic resonance imaging to identify classic and nonclassic forms of ferroportin disease. Blood Cells, Molecules, and Diseases 37:192–196. https://doi.org/10.1016/j.bcmd.2006.08.007
Taher AT, Weatherall DJ, Cappellini MD. Thalassaemia. Lancet. 2018;391(10116):155-167. https://doi.org/10.1016/S0140-6736(17)31822-6
Piperno A (1998) Classification and diagnosis of iron overload. Haematologica 83:447–455.
Moirand R, Mortaji AM, Loréal O, Paillard F, Brissot P, Deugnier Y (1997) A new syndrome of liver iron overload with normal transferrin saturation. Lancet 349:95–97. https://doi.org/10.1016/S0140-6736(96)06034-5
Turlin B, Mendler MH, Moirand R, Guyader D, Guillygomarc'h A, Deugnier Y (2001) Histologic features of the liver in insulin resistance-associated iron overload. A study of 139 patients. American Journal of Clinical Pathology 116:263–270. https://doi.org/10.1309/WWNE-KW2C-4KTW-PTJ5
Riva A (2008) Re-evaluation of clinical and histological criteria for diagnosis of dysmetabolic iron overload syndrome. WJG 14:4745. https://doi.org/10.3748/wjg.14.4745
Deugnier Y, Turlin B (2007) Pathology of hepatic iron overload. WJG 13:4755–4760.
Dongiovanni P, Fracanzani AL, Fargion S, Valenti L (2011) Iron in fatty liver and in the metabolic syndrome: A promising therapeutic target. J Hepatol 55:920–932. https://doi.org/10.1016/j.jhep.2011.05.008
Wood JC (2014) Use of Magnetic Resonance Imaging to Monitor Iron Overload. Hematology/Oncology Clinics of NA 28:747–764. https://doi.org/10.1016/j.hoc.2014.04.002
Angelucci E, Brittenham GM, McLaren CE, Ripalti M, Baronciani D, Giardini C, Galimberti M, Polchi P, Lucarelli G (2000) Hepatic iron concentration and total body iron stores in thalassemia major. N Engl J Med 343:327–331. https://doi.org/10.1056/NEJM200008033430503
Brissot P, Bourel M, Herry D, Verger JP, Messner M, Beaumont C, Regnouard F, Ferrand B, Simon M (1981) Assessment of liver iron content in 271 patients: a re-evaluation of direct and indirect methods. Gastroenterology 80:557–565.
Deugnier Y, Brissot P, Loréal O (2008) Iron and the liver: Update 2008. J Hepatol 48:S113–S123. https://doi.org/10.1016/j.jhep.2008.01.014
Rockey DC, Caldwell SH, Goodman ZD, Nelson RC, Smith AD, American Association for the Study of Liver Diseases (2009) Liver biopsy. Hepatology 49:1017–1044. https://doi.org/10.1002/hep.22742
Villeneuve JP, Bilodeau M, Lepage R, Côté J, Lefebvre M (1996) Variability in hepatic iron concentration measurement from needle-biopsy specimens. J Hepatol 25:172–177.
Hernando D, Levin YS, Sirlin CB, Reeder SB (2014) Quantification of liver iron with MRI: State of the art and remaining challenges. J Magn Reson Imaging 40(5):1003-21. https://doi.org/10.1002/jmri.24584
Wood JC, Zhang P, Rienhoff H, Abi-Saab W, Neufeld EJ (2015) Liver MRI is more precise than liver biopsy for assessing total body iron balance: a comparison of MRI relaxometry with simulated liver biopsy results. Magnetic Resonance Imaging 33:761–767. https://doi.org/10.1016/j.mri.2015.02.016
Abu Rajab M, Guerin L, Lee P, Brown KE (2014) Iron overload secondary to cirrhosis: a mimic of hereditary haemochromatosis? Histopathology 65:561–569. https://doi.org/10.1111/his.12417
Schein A, Enriquez C, Coates TD, Wood JC (2008) Magnetic resonance detection of kidney iron deposition in sickle cell disease: A marker of chronic hemolysis. J Magn Reson Imaging 28:698–704. https://doi.org/10.1002/jmri.21490
França M, Martí-Bonmatí L, Porto G, Silva S, Guimarães S, Alberich-bayarri A, Vizcaíno JR, Miranda HP (2017) Tissue iron quantification in chronic liver diseases using MRI shows a relationship between iron accumulation in liver, spleen, and bone marrow. Clinical Radiology. https://doi.org/10.1016/j.crad.2017.07.022
Sirlin CB, Reeder SB (2010) Magnetic Resonance Imaging Quantification of Liver Iron. Magnetic Resonance Imaging Clinics of North America 18:359–381. https://doi.org/10.1016/j.mric.2010.08.014
Alústiza JMJ, Artetxe JJ, Castiella AA, Agirre CC, Emparanza JIJ, Otazua PP, García-Bengoechea MM, Barrio JJ, Mújica FF, Recondo JAJ (2004) MR quantification of hepatic iron concentration. Radiology 230:479–484. https://doi.org/10.1148/radiol.2302020820
Wood JC (2005) MRI R2 and R2* map** accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients. Blood 106:1460–1465. https://doi.org/10.1182/blood-2004-10-3982
Gandon Y, Olivié D, Guyader D, Aubé C, Oberti F, Sebille V, Deugnier Y (2004) Non-invasive assessment of hepatic iron stores by MRI. Lancet 363:357–362. https://doi.org/10.1016/S0140-6736(04)15436-6
Garbowski MW, Carpenter J-P, Smith G, Roughton M, Alam MH, He T, Pennell DJ, Porter JB (2014) Biopsy-based calibration of T2* magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan. J Cardiovasc Magn Reson 16:1–11. https://doi.org/10.1186/1532-429X-16-40
Hankins JS, McCarville MB, Loeffler RB, Smeltzer MP, Onciu M, Hoffer FA, Li C-S, Wang WC, Ware RE, Hillenbrand CM (2009) R2* magnetic resonance imaging of the liver in patients with iron overload. Blood 113:4853–4855. https://doi.org/10.1182/blood-2008-12-191643
St Pierre TG (2005) Noninvasive measurement and imaging of liver iron concentrations using proton magnetic resonance. Blood 105:855–861. https://doi.org/10.1182/blood-2004-01-0177
Rose C, Vandevenne P, Bourgeois E, Cambier N, Ernst O (2006) Liver iron content assessment by routine and simple magnetic resonance imaging procedure in highly transfused patients. Eur J Haematol 77:145–149. https://doi.org/10.1111/j.0902-4441.2006.t01-1-EJH2571.x
Labranche R, Gilbert G, Cerny M, Vu K-N, Soulières D, Olivié D, Billiard J-S, Yokoo T, Tang A (2018) Liver Iron Quantification with MR Imaging: A Primer for Radiologists. Radiographics 38:392–412. https://doi.org/10.1148/rg.2018170079
Wood JC (2014) Guidelines for quantifying iron overload. Hematology Am Soc Hematol Educ Program 2014:210–215. https://doi.org/10.1182/asheducation-2014.1.210
Wood JC (2015) Estimating tissue iron burden: current status and future prospects. Br J Haematol 170:15–28. https://doi.org/10.1111/bjh.13374
Henninger B, Alustiza J, Garbowski M, Gandon Y (2019) Practical guide to quantification of hepatic iron with MRI. Eur Radiol 30:383-393. https://doi.org/10.1007/s00330-019-06380-9
Hernando D, Kühn JP, Mensel B, et al. R2* estimation using “in-phase” echoes in the presence of fat: The effects of complex spectrum of fat. J Magn Reson Imaging. 2013;37(3):717-726. https://doi.org/10.1002/jmri.23851
Paisant A, Boulic A, Bardou-Jacquet E, et al. Assessment of liver iron overload by 3 T MRI. Abdom Radiol. 2017;42(6):1713-1720. https://doi.org/10.1007/s00261-017-1077-8
Castiella A, Alústiza JM, Emparanza JI, Zapata EM, Costero B, Díez MI (2010) Liver iron concentration quantification by MRI: are recommended protocols accurate enough for clinical practice? Eur Radiol 21:137–141. https://doi.org/10.1007/s00330-010-1899-z
d’Assignies G, Paisant A, Bardou-Jacquet E, et al. Non-invasive measurement of liver iron concentration using 3-Tesla magnetic resonance imaging: validation against biopsy. Eur Radiol. 2018;28(5):2022-2030. https://doi.org/10.1007/s00330-017-5106-3
Wood JC, Ghugre N (2008) Magnetic Resonance Imaging Assessment of Excess Iron in Thalassemia, Sickle Cell Disease and Other Iron Overload Diseases. Hemoglobin 32:85–96. https://doi.org/10.1080/03630260701699912
St Pierre TG, El-Beshlawy A, Elalfy M, Jefri Al A, Zir Al K, Daar S, Habr D, Kriemler-Krahn U, Taher A (2013) Multicenter validation of spin-density projection-assisted R2-MRI for the non-invasive measurement of liver iron concentration. Magn Reson Med 71:2215–2223. https://doi.org/10.1002/mrm.24854
Yokoo T, Browning JD. Fat and iron quantification in the liver: past, present, and future. Top Magn Reson Imaging. 2014;23(2):73-94.
Meloni A, Luciani A, Positano V, et al. Single region of interest versus multislice T2* MRI approach for the quantification of hepatic iron overload. J Magn Reson Imaging. 2011;33(2):348-355. https://doi.org/10.1002/jmri.22417
Henninger B, Zoller H, Rauch S, Finkenstedt A, Schocke M, Jaschke W, Kremser C (2015) R2* Relaxometry for the Quantification of Hepatic Iron Overload: Biopsy-Based Calibration and Comparison with the Literature. Fortschr Röntgenstr 187:472–479. https://doi.org/10.1055/s-0034-1399318
França M, Alberich-Bayarri A, Martí-Bonmatí L, Oliveira P, Costa FE, Porto G, Vizcaíno JR, Gonzalez JS, Ribeiro E, Oliveira J, Miranda HP (2017) Accurate simultaneous quantification of liver steatosis and iron overload in diffuse liver diseases with MRI. Abdominal Radiology. https://doi.org/10.1007/s00261-017-1048-0
Hernando D, Wells SA, Vigen KK, Reeder SB (2015) Effect of hepatocyte-specific gadolinium-based contrast agents on hepatic fat-fraction and R2(⁎). Magnetic Resonance Imaging 33:43–50. https://doi.org/10.1016/j.mri.2014.10.001
Kirk P, He T, Anderson LJ, Roughton M, Tanner MA, Lam WWM, Au WY, Chu WCW, Chan G, Galanello R, Matta G, Fogel M, Cohen AR, Tan RS, Chen K, Ng I, Lai A, Fucharoen S, Laothamata J, Chuncharunee S, Jongjirasiri S, Firmin DN, Smith GC, Pennell DJ (2010) International reproducibility of single breathhold T2* MR for cardiac and liver iron assessment among five thalassemia centers. J Magn Reson Imaging 32:315–319. https://doi.org/10.1002/jmri.22245
Tanner MA, He T, Westwood MA, Firmin DN, Pennell DJ. Multi-center validation of the transferability of the magnetic resonance T2* technique for the quantification of tissue iron. Haematologica. 2006;91(10):1388-1391.
Sussman MS, Ward R, Kuo KHM, Tomlinson G, Jhaveri KS (2020) Impact of MRI technique on clinical decision-making in patients with liver iron overload: comparison of FerriScan- versus R2*-derived liver iron concentration. Eur Radiol 30:1959-1968. https://doi.org/10.1007/s00330-019-06450-y
Meloni A, Rienhoff HY, Jones A, Pepe A (2013) The use of appropriate calibration curves corrects for systematic differences in liver R2* values measured using different software packages. Br J Haematol 161(6):888-91. https://doi.org/10.1111/bjh.12296.
Wood JC, Zhang P, Rienhoff H, Abi-Saab W, Neufeld E (2014) R2 and R2* are equally effective in evaluating chronic response to iron chelation. Am J Hematol 89:505–508. https://doi.org/10.1002/ajh.23673
Storey P, Thompson AA, Carqueville CL, Wood JC, de Freitas RA, Rigsby CK (2007) R2* imaging of transfusional iron burden at 3T and comparison with 1.5T. J Magn Reson Imaging 25:540–547. https://doi.org/10.1002/jmri.20816
Meloni A, Positano V, Keilberg P, De Marchi D, Pepe P, Zuccarelli A, Campisi S, Romeo MA, Casini T, Bitti PP, Gerardi C, Lai ME, Piraino B, Giuffrida G, Secchi G, Midiri M, Lombardi M, Pepe A (2012) Feasibility, reproducibility, and reliability for the T2* iron evaluation at 3 T in comparison with 1.5 T. Magn Reson Med 68:543–551. https://doi.org/10.1002/mrm.23236
Li J, Lin H, Liu T, Zhang Z, Prince MR, Gillen K, Yan X, Song Q, Hua T, Zhao X, Zhang M, Zhao Y, Li G, Tang G, Yang G, Brittenham GM, Wang Y (2018) Quantitative susceptibility map** (QSM) minimizes interference from cellular pathology in R2* estimation of liver iron concentration. J Magn Reson Imaging 48:1069–1079. https://doi.org/10.1002/jmri.26019
Hernando D, Kramer JH, Reeder SB (2013) Multipeak fat-corrected complex R2* relaxometry: Theory, optimization, and clinical validation. Magn Reson Med 70:1319–1331. https://doi.org/10.1002/mrm.24593
Martí-Bonmatí L, Alberich-Bayarri A, Sánchez-González J (2011) Overload hepatitides: quanti-qualitative analysis. Abdom Imaging 37:180–187. https://doi.org/10.1007/s00261-011-9762-5
Kühn J-P, Hernando D, del Rio AM, Evert M, Kannengiesser S, Völzke H, Mensel B, Puls R, Hosten N, Reeder SB (2012) Effect of multipeak spectral modelling of fat for liver iron and fat quantification: correlation of biopsy with MR imaging results. Radiology 265:133–142. https://doi.org/10.1148/radiol.12112520/-/DC1
Serai SD, Smith EA, Trout AT, Dillman JR (2018) Agreement between manual relaxometry and semi-automated scanner-based multi-echo Dixon technique for measuring liver T2* in a pediatric and young adult population. Pediatr Radiol 48:94–100. https://doi.org/10.1007/s00247-017-3990-y
Wang Y, Spincemaille P, Liu Z, et al. Clinical quantitative susceptibility map** (QSM): Biometal imaging and its emerging roles in patient care. J Magn Reson Imaging. 2017;46(4):951-971. https://doi.org/10.1002/jmri.25693
Schwenzer NF, Machann J, Haap MM, Martirosian P, Schraml C, Liebig G, Stefan N, Häring H-U, Claussen CD, Fritsche A, Schick F (2008) T2* relaxometry in liver, pancreas, and spleen in a healthy cohort of one hundred twenty-nine subjects-correlation with age, gender, and serum ferritin. Invest Radiol 43:854–860. https://doi.org/10.1097/RLI.0b013e3181862413
Grassedonio E, Meloni A, Positano V, et al. Quantitative T2* magnetic resonance imaging for renal iron overload assessment: normal values by age and sex. Abdom Imaging. 2015;40(6):1700-1704. https://doi.org/10.1007/s00261-015-0395-y
França M, Martí-Bonmatí L, Silva S, Oliveira C, Alberich-Bayarri A, Vilas Boas F, Pessegueiro-Miranda H, Porto G (2017) Optimizing the management of hereditary haemochromatosis: the value of MRI R2* quantification to predict and monitor body iron stores. Br J Haematol 183:491–493. https://doi.org/10.1111/bjh.14982
Funding
This paper had no funding.
Author information
Authors and Affiliations
Contributions
MF had the idea for the article, JGC and MF performed the literature search and data analysis, MF drafted the work and both authors critically revised the work and approved the final version.
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
França, M., Carvalho, J.G. MR imaging assessment and quantification of liver iron. Abdom Radiol 45, 3400–3412 (2020). https://doi.org/10.1007/s00261-020-02574-8
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00261-020-02574-8