Abstract
Biomechanics is the development, extension, and application of mechanics for the purpose of understanding better the influence of mechanical loads on the structure, properties, and function of living things. Biomechanics focuses on design and analysis, each of which is the foundation of engineering. CT scan data is widely used to make realistic investigations on the mechanical behavior of bone structures using Finite Element Analysis (FEA). The purpose of this paper is to create anatomically accurate, 3D finite element models of the right human proximal femur for 17, 32, and 40-year-old-male patients using individual CT scan data. Thus, allowing the biomechanical analysis of the male right human proximal femur of different age groups loaded under physiologic forces at constant angle of 28°, i.e., at varying body weights of 70 and 75 kg, respectively which is shared equally by the lower limbs, that affect femur during weight bearing acting at different conditions and to determine the total deformation, equivalent Von-Mises stress distribution, maximum principal stress distribution, and fatigue tool throughout the whole femur, and comparing the results. Analysis of this model will provide data unavailable at this time to orthopedic surgeons, engineers, and researchers of human orthopedics.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Hanumantharaju HG, Shivanand HK (2010) Strength analysis and comparison of SS316L, Ti-6AI-4 V and Ti-35Nb-7Zr-5Ta used as orthopaedic implant materials by FEA, 2nd international conference on chemical, biological and environmental engineering (ICBEE 2010): 101–105
Gdoutos EE, Raftopoulos DD, Baril JD (1982) A critical review of the biomechanical stress analysis of the human femur. J Biomater 3:2–8
Nather A, Ong HJC, Aziz Z (2005) Bone grafts and bone substitutes—basic science and clinical applications. World Scientific Publishing Co. Pte. Ltd, Structure of bone; 5
Rohlmann A, Mossner U, Bergmann G, Kolbel R (1982) Finite element analysis and experimental investigation of stresses in a femur. J Biomed Eng 4:242–246
Wille H, Rank E, Yosibash Z (2012) Prediction of the mechanical response of the femur with uncertain elastic properties. J Biomech 45(7):1140–1148
Grassi L, Schoileo E, Taddei F, Zani L, Juszczyk M, Cristofolini L, Viceconti M (2012) Accuracy of finite element predictions in sideways load configurations for the proximal human femur. J Biomech 45:394–399
Trabelsi N, Yosibash Z, Milgrom C (2009) Validation of subject-specific automated p-FE analysis of the proximal femur. J Biomech 42: 234–241
Yosibash Z, Trabelsi N, Milgrom C (2007a) Reliable simulations of the human proximal femur by high-order finite element analysis validated by experimental observations. J Biomech 40: 3688–3699
Yosibash Z, Padan R, Joscowicz L, Milgrom C (2007b) A CT-based high-order finite element analysis of the human proximal femur compared to in vitro experiments. ASME J Biomech Eng 129(3): 297–309
Taylor ME, Tanner KE, Freeman MAR, Yettram AL (1996) Stress and strain distribution within the intact femur: compression or bending? Medical Eng Phy, Elsevier Science Ltd 18(2):122–131
Jun-hai Z, Shu-fang MA, Wue-ying W (2009) Finite element analysis of femur stress under bending moment and compression load, 2nd international conference on biomedical engineering and informatics (BMEI 2009): 1–4
Bitsakos JK, Fisher I, Amis AA (2005) The effect of muscle loading on the simulation of bone remodelling in the proximal femur. J Biomech 38: 133–139
Duda GN, Schneider E, Chao EYS (1997) Internal forces and moments in the femur during walking. J Biomech 30(9): 933–941
Simoes JA, Vaz MA, Blatcher S, Taylor M (2000) Influence of head constraint and muscle forces on the strain distribution within the intact femur. Med Eng Phys 22:453–459
Brand RA, Crowninshield RD, Wittstock CE, Pederson DR, Clark CR, Van Krieken FM (1982) A model of lower extremity muscular anatomy. J Biomech 104: 304–310
Amornsamankul S, Kaorapapong K, Wiwatanapataphee B (2010) Three-dimensional simulation of femur bone and implant in femoral canal using finite element method. Int J Math Comput Simulation 4(4): 171–178
Kulkarni MS, Sathe SR (2008) Experimental determination of material properties of cortical cadeveric femur bone. Trends Biomater Artif Organs 22(1):9–15
Burgers TA, Mason J, Niebur G, Ploeg HL (2008) Compressive properties of trabecular bone in the distal femur. J Biomech 4: 1077–1085
Heller MO, Bergmann G, Deuretzbacher G, Claes L, Haas NP, Duda GN (2001) Influence of femoral anteversion on proximal femoral loading: measurement and simulation in four patients. Clinical Biomech 16: 644–649
Materialise’s Interactive Medical Image Control System (MIMICS) 10.01: User Manual:Materialise, http://www.materialise.com/mimics/
Testi D, Viceconti M, Baruffaldi F, Cappello A (1999) Risk of fracture in elderly patients: a new predictive index based on bone mineral density and finite element analysis. Comput Methods Programs Biomed 60:23–33
Viceconti M, Bellingeri L, Cristofolini L, Toni A (1998) A comparative study on different methods of automatic mesh generation of human femurs. Medical Eng Phy 20: 1–10
Nareliya R, Kumar V (2011) Biomechanical analysis of human femur bone. Int J Eng Sci Technol 3(4): 3090–3094
Acknowledgments
The authors would like to thank Dr. (Mrs.) Shobha Katheria, Principal Medical Officer, Ordnance Factory Hospital, Itarsi, M.P. India, Dr Rakesh Tirkey, Assistant Professor of Medical College, Jabalpur, M.P, India and Dr. Pushpraj Bhatele, for providing medical imaging data and supporting our work.
Conflict of Interest Statement
None of the authors have any conflict of interest to declare that could bias the presented work.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer India
About this paper
Cite this paper
Francis, A. et al. (2013). Finite Element Modeling of Human Femur Using CT Data: A Biomechanical Analysis. In: Kumar, V., Bhatele, M. (eds) Proceedings of All India Seminar on Biomedical Engineering 2012 (AISOBE 2012). Lecture Notes in Bioengineering. Springer, India. https://doi.org/10.1007/978-81-322-0970-6_8
Download citation
DOI: https://doi.org/10.1007/978-81-322-0970-6_8
Published:
Publisher Name: Springer, India
Print ISBN: 978-81-322-0969-0
Online ISBN: 978-81-322-0970-6
eBook Packages: EngineeringEngineering (R0)