Metal-on-Metal Hip Implants: Progress and Problems

  • Chapter
  • First Online:
Biomedical Applications of Metals

Abstract

Once perceived as the future of hip arthroplasty, metal-on-metal (MoM) prostheses have since infamously fallen out of favor. The in vitro advantages of MoM implants, which included improved wear properties, reduced osteolysis, and allowed for the use of larger femoral heads to improve stability, have since been far outweighed by the local and systemic reactions associated with metal-on-metal implants. These adverse reactions stem from local release of chromium and cobalt ions, which result in immune responses locally and the formation of effusions and large solid masses known as pseudotumors or systemic effects on various organ systems. With over 1 million MoM prostheses in circulation worldwide, the revision burden of these devices is expected to increase, and a thorough understanding of the clinical manifestations of adverse reactions and revision strategies is essential for revision arthroplasty surgeons.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free ship** worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free ship** worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  • Allen MJ, Myer BJ, Millett PJ (1997) The effects of particulate cobalt, chromium and cobalt-chromium alloy on human osteoblast-like cells in vitro. J Bone Jt Surg (Br) 79:475–482

    Article  CAS  Google Scholar 

  • Amstutz HC (1996) Editorial comment. Clin Orthop Relat Res. Metal on Metal Hip Protheses: Past Performance and Future Directions 329: S2–S3

    Google Scholar 

  • Anissian HL, Stark A, Gustafson A, Good V, Clarke IC (1999) Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene. Acta Orthop Scand 70:78e582

    Article  Google Scholar 

  • Anissian HL, Stark A, Grandberg B, Good V, Bucht E (2002) Cobalt ions influence proliferation and function of human osteoblast-like cells. Acta Orthop Scand 73:369–374

    Article  PubMed  Google Scholar 

  • Australian Orthopaedic Association Nation Joint Replacement Registry (2010) Annual report. Australian Orthopaedic Association, Adelaide, SA, Australia

    Google Scholar 

  • Bernstein M, Walsh A, Petit A, Zukor DJ, Huk OL, Antoniou J (2011) Femoral head size does not affect ion values in metal-on-metal total hips. Clin Orthop Relat Res 469(6):1642–1650

    Article  PubMed  Google Scholar 

  • Berry DJ, Von Knoch M, Schleck CD, Harmsen WS (2005) Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Jt Surg Am 87: 2456e2463

    Google Scholar 

  • Bizot P, Nizard R, Hamadouche M, Hannaouche D, Sedel L (2001) Prevention of wear and osteolysis: alumina-on-alumina bearing. Clin Orthop Relat Res 393:85–93

    Article  Google Scholar 

  • Black J (1988) Does corrosion matter? J Bone Jt Surg (Br) 70(4):517–520

    Article  CAS  Google Scholar 

  • Bolognesi MP, Ledford CK (2015) Metal-on-metal total hip arthroplasty: patient evaluation and treatment. J Am Acad Orthop Surg 23:724–731

    Article  PubMed  Google Scholar 

  • Bonassi S, Hagmar L, Strömberg U, Montagud AH, Tinnerberg H, Forni A, Heikkila P, Wanders S, Wilhardt P, Hansteen IL, Knudsen LE, Norppa H (2000) Chromosomal aberrations in lymphocytes predict human cancer independently of exposure to carcinogens. Eur Study Group Cytogenet Biomark Health Cancer Res 60:1619–1625

    CAS  Google Scholar 

  • Bosker BH, Ettema HB, van Rossum M, Boomsma MF, Kollen BJ, Maas M, Verheyen CC (2015) Pseudotumor formation and serum ions after large head metal-on-metal stemmed total hip replacement: risk factors, time course and revisions in 706 hips. Arch Orthop Trauma Surg 135:417–425

    Article  CAS  PubMed  Google Scholar 

  • Bozic KJ, Kurtz S, Lau E, Ong K, Chiu V, Vail TP, Rubash HE, Berry DJ (2009) The epidemiology of bearing surface usage in total hip arthroplasty in the United States. J Bone Jt Surg Am 91(7):1614–1620

    Article  Google Scholar 

  • Brewster DH, Stockton DL, Reekie A, Ashcroft GP, Howie CR, Porter DE, Black RJ (2013) Risk of cancer following primary total hip replacement or primary resurfacing arthroplasty of the hip: a retrospective cohort study in Scotland. Br J Cancer 108(9):1883–1890

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  • Case CP, Langkamer VG, Howell RT, Webb J, Standen G, Palmer M, Kemp A, Learmonth ID (1996) Preliminary observations on possible premalignant changes in bone marrow adjacent to worn total hip arthroplasty implants. Clin Orthop (Suppl) 329:269–279

    Article  Google Scholar 

  • Chang EY, McAnally JL, Van Horne JR, Statum S, Wolfson T, Gamst A, Chung CB (2012) Metal-on-metal total hip arthroplasty: do symptoms correlate with MR imaging findings? Radiology 265(3):848–857

    Article  PubMed  Google Scholar 

  • Charnley J (1961) Arthroplasty of the hip: a new operation. Lancet 1:1129–1132

    Article  CAS  PubMed  Google Scholar 

  • Choi HJ, Lim SJ, Park YS, Lee SY (2015) Simple and robust ICP-MS method for simultaneous determination of serum Co and Cr in routine clinical practice. Clin Chim Acta 439:91–96

    Article  CAS  PubMed  Google Scholar 

  • Daley B, Doherty AT, Fairman B, Case CP (2004) Wear debris from hip or knee replacements causes chromosomal damage in human cells in tissue culture. J Bone Jt Surg (Br) 86:598–606

    Article  CAS  Google Scholar 

  • Davies AF, Willert HG, Campbell PA, Learmonth ID, Case CP (2005) An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements. J Bone Jt Surg (Am) 87:18–27

    Article  CAS  Google Scholar 

  • De Haan R, Pattyn C, Gill HS (2008) Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Jt Surg Br 90(10):1291–1297

    Article  Google Scholar 

  • De Smet K, De Haan R, Calistri A, Campbell PA, Ebramzadeh E, Pattyn C, Gill HS (2008) Metal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing. J Bone Jt Surg (Am) 90:202–208

    Article  Google Scholar 

  • De Steiger RN, Hang JR, Miller LN, Graves SE, Davidson DC (2011) Five-year results of the ASR XL acetabular system and the ASR hip resurfacing system: an analysis from the Australian Orthopaedic Association National Joint Replacement Registry. J Bone Jt Surg (Am) 93(24):2287–2293

    Article  Google Scholar 

  • Delaunay C, Petit I, Learmonth ID, Oger P, Vendittoli PA (2010) Metal-on-metal bearings total hip arthroplasty: the cobalt and chromium ions release concern. Orthop Traumatol Surg Res 96(8):894–904

    Article  CAS  PubMed  Google Scholar 

  • Donaldson FE, Coburn JC, Siegel KL (2014) Total hip arthroplasty head-neck contact mechanics: a stochastic investigation of key parameters. J Biomech 47(7):1634–1641

    Article  PubMed  Google Scholar 

  • Duggan PJ (2013) Current literature and imaging techniques of aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL). Clin Radiol 68(11):1089–1096

    Article  CAS  PubMed  Google Scholar 

  • Dyrkacz RM, Brandt JM, Ojo OA, Turgeon TR, Wyss UP (2013) The influence of head size on corrosion and fretting behaviour at the head-neck interface of artificial hip joints. J Arthroplasty 28(6):1036–1040

    Article  PubMed  Google Scholar 

  • Engh CA, MacDonald SJ, Sritulanondha S, Korczak A, Naudie D, Engh C (2014) Metal ion levels after metal-on-metal total hip arthroplasty: a five-year, prospective randomized trial. J Bone Jt Surg Am 96(6):448–455

    Article  CAS  Google Scholar 

  • Grammatopolous G, Pandit H, Kwon YM, Gundle R, McLardy-Smith P, Beard DJ, Murray DW, Gill HS (2009) Hip resurfacings revised for inflammatory pseudotumor have a poor outcome. J Bone Jt Surg Br 91:1019–1024

    Article  Google Scholar 

  • Hart AJ, Sabah SA, Bandi AS, Maggiore P, Tarassoli P, Sampson BA, Skinner J (2011) Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement. J Bone Jt Surg Br 93(10):1308–1313

    Article  CAS  Google Scholar 

  • Hart AJ, Satchithananda K, Liddle AD, Sabah SA, McRobbie D, Henckel J, Cobb JP, Skinner JA, Mitchell AW (2012) Pseudotumors in association with well-functioning metal-on-metal hip prostheses: a case-control study using three-dimensional computed tomography and magnetic resonance imaging. J Bone Jt Surg Am 94(4):317–325

    Article  Google Scholar 

  • IARC (2006). Metallic cobalt particles. (With or without tungsten carbide). Cobalt metal with tungsten carbide (Group 2A). Cobalt metal without tungsten carbide (group 2B). Cobalt sulfate and other soluble cobalt (II) salts (group 2B). IARC Monographs 2006; 86:37 http://monographs.iarc.fr/ENG/Monographs/vol86/volume86.pdf

  • Ikeda T, Takahashi K, Kabata T, Sakagoshi D, Tomita K, Yamada M (2010) Polyneuropathy caused by cobalt chromium metallosis after THA. Muscle Nerve 42:140–143

    Article  PubMed  Google Scholar 

  • Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV (2010) Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Jt Surg Br 92: 38e46

    Google Scholar 

  • Learmonth ID, Young C, Rorabeck C (2007) The operation of the century: total hip replacement. Lancet 370:1508–1519

    Article  PubMed  Google Scholar 

  • Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone and Jt Surg Am. 60:217–220

    Article  CAS  Google Scholar 

  • Lombardi AV Jr, Barrack RL, Berend KR, Cuckler JM, Jacobs JJ, Mont MA, Schmalzried TP (2012) The hip society: algorithmic approach to diagnosis and management of metal-on-metal arthroplasty. J Bone Jt Surg Br 94(11 suppl A) 14–18

    Google Scholar 

  • MacDonald SJ, McCalden RW, Chess DG, Bourne RB, Rorabeck CH, Cleland D, Leung F (2003) Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial. Clin Orthop Rel Res 406:282–296

    Article  Google Scholar 

  • Makela KT, Visuri T, Pulkkinen P, Eskelinen A, Remes V, Virolainen P, Junnila M, Pukkala E (2012) Risk of cancer with metal-on-metal hip replacements: population based study. Br Med J 345:e4646. https://doi.org/10.1136/bmj.e4646

    Article  Google Scholar 

  • Makela KT, Visuri T, Pulkkinen P, Eskelinen A, Remes V, Virolainen P, Junnila M, Pukkala E (2014) Cancer incidence and cause-specific mortality in patients with MoM hip replacements in Finland. Acta Orthop 85(1):32–38

    Article  PubMed  PubMed Central  Google Scholar 

  • Mann SM, Kunz M, Ellis RE, Rudan JF (2016) Component position and metal ion levels in computer-navigated hip resurfacing arthroplasty. J Arthroplasty 32(1):110–124

    Google Scholar 

  • Marker M, Grubl A, Riedl O, Heinze G, Pohanka E, Kotz R (2008) MoM hip implants: do they impair renal function in the long term? Arch Orthop Trauma Surg 128:915–919

    Article  PubMed  Google Scholar 

  • McDermott PH, Delaney RL, Egan JD, Sullivan JF (1966) Myocardosis and cardiac failure in men. JAMA 198:163–166

    Article  Google Scholar 

  • Mayo Clinic (2012) Evaluation of metal-on-metal wear of orthopaedic implants – the role of serum chromium and cobalt analysis. Mayo Med Lab: Communique 37:1–8

    Google Scholar 

  • McKee GK, Watson-Farrar J (1966) Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Jt Surg Br 48:245–259

    Article  CAS  Google Scholar 

  • Medicine and Healthcare Products Regulatory Agency (2010) Medical device alert: all metal-on-metal (MoM) hip replacements. Tech. Rep. MDA/2012/008

    Google Scholar 

  • Medicines and Healthcare Products Regulatory Agency (2012) Medical device alert (MDA/2012/036): all metal-on-metal (MoM) hip replacements; 2012

    Google Scholar 

  • Morin Y (1967) Quebec beer drinkers cardiomyopathy: etiologic associations. Can Med Assoc J 97:926–928

    CAS  PubMed  PubMed Central  Google Scholar 

  • Mosier BA, Maynard L, Sotereanos NG, Sewecke JJ (2016) Progressive cardiomyopathy in a patient with elevated cobalt ion levels and bilateral metal-on-metal hip arthroplasties. Am J Orthop 45(3):E132–E135

    PubMed  Google Scholar 

  • Nangaku M (2009) Novel therapeutic approach targeting the HIF-HRE system in the kidney. Adv Exp Med Biol 645:81–86

    Article  CAS  PubMed  Google Scholar 

  • National Joint Registry for England and Wales (2010) Seventh annual report. National Joint Registry Centre, Hemel Hempstead, Hertfordshire, UK

    Google Scholar 

  • Newton AW, Ranganath L, Armstrong C, Peter V, Roberts NB (2012) Differential distribution of cobalt, chromium and nickel between whole blood, plasma and urine in patients after metal-on-metal (MoM) hip arthroplasty. J Orthop Res 30(10):1640–1646

    Article  CAS  PubMed  Google Scholar 

  • Nishii T, Sakai T, Takao M, Yoshikawa H, Sugano N (2012) Ultrasound screening of peri-articular soft tissue abnormality around metal-on-metal bearings. J Arthroplasty 27(6):895–900

    Article  PubMed  Google Scholar 

  • Oldenburg M, Wegner R, Baur X (2009) Severe cobalt intoxication due to prosthesis wear in repeated total hip arthroplasty. J Arthroplasty 24(5): 825.e15–e20

    Google Scholar 

  • Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gibbons CL, Ostlere S, Athanasou N, Gill HS, Murray DW (2008) Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Jt Surg Br 90:e847–e851

    Article  Google Scholar 

  • Raghunathan VK, Devey M, Hawkins S, Hails L, Davis SA, Mann S, Chang IT, Ingham E, Malhas A, Vaux DJ, Lane JD Case CP (2013) Influence of particle size and ROS on cobalt chrome nanoparticle-mediated genotoxicity. Biomaterials 3559–3570

    Google Scholar 

  • Ring G, O’Mullane J, O’Riordan A, Furey A (2016) Trace metal determination as it relates to metallosis of orthopaedic implants: Evolution and current status. Clin Biochem 49(7–8):617–635

    Google Scholar 

  • Rodushkin I, Ödman F, Branth S (1999) Multielement analysis of whole blood by high resolution inductively coupled plasma mass spectrometry. Fresen J Anal Chem 364(4):338–346

    Article  CAS  Google Scholar 

  • Sabah SA, Mitchell AW, Henckel J, Sandison A, Skinner JA, Hart AJ (2011) Magnetic resonance imaging findings in painful metal-on-metal hips: a prospective study. J Arthroplasty 26(1):71–76

    Article  PubMed  Google Scholar 

  • Sarhadi VK, Parkkinen J, Reito A, Nieminen J, Porkka N, Wirtanen T, Laitinen M, Eskelinen A, Knuutila S (2015) Genetic alterations in periprosthetic soft tissue masses from patients with MoM THA. Mutat Res 781: 1–6

    Google Scholar 

  • Savarino L, Cadossi M, Chiarello E, Fotia C, Greco M, Baldini N, Giannini S (2014) How do metal ion levels change over time in hip resurfacing patients? a cohort study. Sci World J 29:19–25

    Google Scholar 

  • Seghizzi P, D’Adda F, Borleri D, Barbic F, Mosconi G (1994) Cobalt myocardiopathy: a critical review of the literature. Sci Total Environ 150:105–109

    Article  CAS  PubMed  Google Scholar 

  • Seiler HG, Sigel H, Siegel A (eds) (1988) Handbook on the toxicity of inorganic compounds, 259. Marcel Dekker, New York (NY)

    Google Scholar 

  • Seppanen M, Makela K, Virolainen P, Remes CV, Pulkkinen P, Eskelinen A (2012) Hip resurfacing arthroplasty: short-term survivorship of 4,401 hips from the Finnish Arthroplasty Register. Acta Orthop 83:207

    Article  PubMed  PubMed Central  Google Scholar 

  • Shrivastava K, Ram MS, Bansal A, Singh SS, Ilavazhagan G (2008) Co-supplementation promotes hypoxic tolerance and facilitates acclimatization to hypobaric hypoxia in rat brain. High Altitude Med Biol 9:63–75

    Article  CAS  Google Scholar 

  • Sidaginamale RP, Joyce TJ, Lord JK, Jefferson R, Blain PG, Nargol AVF, Langton DJ (2013) Blood metal ion testing is an effective screening tool to identify poorly performing metal-on-metal bearing surfaces. Bone Jt Res 2(5):84–95

    Article  CAS  Google Scholar 

  • Smith AJ, Dieppe P, Howard PW, Bolm AW (2012a) Failure rates of metal-on-metal hip resurfacings: analysis of data from the National Joint Registry for England and Wales. Lancet 380(9855):1759–1766

    Article  PubMed  Google Scholar 

  • Smith AJ, Dieppe P, Porter M, Blom AW (2012b) Risk of cancer in first seven years after metal-on-metal hip replacement compared with other bearings and general population: linkage study between the National Joint Registry of England and Wales and hospital episode statistics. BMJ 344:2383

    Article  Google Scholar 

  • Smith-Petersen MN (1948) The classic: evolution of mold arthroplasty of the hip joint. J Bone Joint Surg 30B:L:59

    Google Scholar 

  • Steens W, Von Foerster G, Katzer A (2006) Severe cobalt poisoning with loss of sight after ceramic-metal pairing in a hip—case report. Acta Orthop 77(5):830–832

    Article  PubMed  Google Scholar 

  • Toms AP, Smith-Bateman C, Malcolm PN, Cahir J, Graves M (2010) Optimization of metal artifact reduction (MAR) sequences for MRI of total hip prostheses. Clin Radiol 65(6):447–452

    Article  CAS  PubMed  Google Scholar 

  • Treacy R, McBryde C, Shears E, Pynsent P (2011) Birmingham hip resurfacing: a minimum follow-up of ten years. J Bone Jt Surg Br. 93(1):27–33

    Article  CAS  Google Scholar 

  • Udofia IJ, ** ZM (2003) Elastohydrodynamic lubrication analysis of metal-on-metal hip-resurfacing prostheses. J Biomech 36:537–544

    Article  CAS  PubMed  Google Scholar 

  • Vendittoli PA, Mottard S, Roy AG, Dupont C, Lavigne M (2007) Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip. J Bone Jt Surg Br 89(4):441–448

    Article  Google Scholar 

  • Visuri T, Pukkala E, Paavolainen P, Pulkkinen P, Riska EB (1996) Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty. Clin Orthop (Suppl) 329:S280–S289

    Article  Google Scholar 

  • Visuri T, Pulkkinen P, Paavolainen P, Pukkala E (2010) Cancer risk is not increased after conventional hip arthroplasty: a natiowide study from the Finnish Arthroplasty Register with follow-up of 24,636 patients for a mean of 13 years. Acta Orthop 81:77–81

    Article  PubMed  PubMed Central  Google Scholar 

  • Watanabe Y, Shiba N, Matsuo S, Higuchi F, Tagawa Y, Inoue A (2000) Biomechanical study of the resurfacing hip arthroplasty: finite element analysis of the femoral component. J Arthroplasty 15:505–511

    Article  CAS  PubMed  Google Scholar 

  • Watters TS, Cardona DM, Menon KS, Vinson EN, Bolognesi MP, Dodd LG (2010) Aseptic lymphocyte-dominated vasculitis-associated lesion: a clinicopathologic review of an under recognized cause of prosthetic failure. Am J Clin Pathol 134:886–893

    Article  PubMed  Google Scholar 

  • Wiles P (1957) The surgery of the osteo-arthritis hip. Br J Surg 45:488–497

    Article  Google Scholar 

  • Wyles CC, Larson DR, Houdek MT, Sierra RJ, Trousdale RT (2013) Utility of synovial fluid aspirations in failed metal-on-metal total hip arthroplasty. J Arthroplasty 28(5):818–823

    Article  PubMed  Google Scholar 

  • Yanny S, Cahir JG, Barker T, Wimhurst J, Nolan JF, Goodwin RW, Marshall T, Toms AP (2012) MRI of aseptic lymphocyte vasculitis-associated lesions in metal-on-metal hip replacements. Am J Roentgenol 198:1394–1402

    Article  Google Scholar 

  • Zywiel MG, Brandt JM, Overgaard AC, Turgeon TR, Syed KA (2013) Fatal cardiomyopathy after revision total hip replacement for fracture of a ceramic liner. Bone Jt J 95(B): 31–37

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Neil P. Sheth .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer International Publishing AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Neuwirth, A.L., Ashley, B.S., Hardaker, W.M., Sheth, N.P. (2018). Metal-on-Metal Hip Implants: Progress and Problems. In: Rai, M., Ingle, A., Medici, S. (eds) Biomedical Applications of Metals. Springer, Cham. https://doi.org/10.1007/978-3-319-74814-6_3

Download citation

Publish with us

Policies and ethics

Navigation