Multifocal Intraocular Lenses: AT LISA 809 Diffractive Bifocal Intraocular Lens

  • Chapter
  • First Online:
Multifocal Intraocular Lenses

Part of the book series: Essentials in Ophthalmology ((ESSENTIALS))

  • 742 Accesses

Abstract

The AT LISA 809 (Carl Zeiss Meditec AG) is an aspheric bifocal biconvex diffractive IOL with near vision add of +3.75 D over the distance power.

Forty-eight eyes of 24 bilateral cataract patients with age ranging between 47 and 77 years were implanted with AT LISA 809 IOL. Distance and near visual acuities, contrast sensitivity, defocus curve and ocular optical performance, quality of vision and patient satisfaction were reported.

At 6 months after surgery, a statistical significant improvement was observed in the uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA) and distance corrected near visual acuity (DCNVA) (p < 0.01). The profile of the defocus curve shows 2 peaks of maximum vision for defocus levels of 0.00 D and −2.50 D. Postoperative intraocular optical quality showed no significant amounts of these aberrometer parameters. In this study, it was found that halos are the most prominent visual symptom, and the spectacle independence was 82.1%.

The AT LISA 809 IOL multifocal IOL provides a good visual rehabilitation after cataract surgery.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 69.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 89.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free ship** worldwide - see info
Hardcover Book
USD 119.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free ship** worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. Lane SS, Morris M, Nordan L, Packer M, Tarantino N, Wallace RB III. Multifocal intraocular lenses. Ophthalmol Clin N Am. 2006;19(1):89–105.

    Google Scholar 

  2. Walkow T, Liekfeld A, Anders N, Pham DT, Hartmann C, Wollensak J. A prospective evaluation of a diffractive versus a refractive designed multifocal intraocular lens. Opthalmology. 1997;104:1380–6.

    Article  CAS  Google Scholar 

  3. Bellucci R. Multifocal intraocular lenses. Curr Opin Ophthalmol. 2005;16:33–7.

    Article  Google Scholar 

  4. Hoffman RS, Fine IH, Packer M. Refractive lens exchange with a multifocal intraocular lens. Curr Opin Ophthalmol. 2003;14:24–30.

    Article  Google Scholar 

  5. Richter-Mueksch S, Weghaupt H, Skorpik C, et al. Reading performance with a refractive multifocal and a diffractive bifocal intraocular lens. J Cataract Refract Surg. 2002;28:1957–63.

    Article  Google Scholar 

  6. Alió JL, Elkady B, Ortiz D, Bernabeu G. Clinical outcomes and intraocular quality of a diffractive multifocal intraocular lens with asymmetrical light distribution. J Cataract Refract Surg. 2008;34:942–8.

    Article  Google Scholar 

  7. Mojzis P, Kukuckova L, Majerova K, Liehneova K, Piñero DP. Comparative analysis of the visual performance after cataract surgery with implantation of a bifocal or trifocal diffractive IOL. J Refract Surg. 2014;30:666–72.

    Article  Google Scholar 

  8. Alfonso FJ, Fernández-Vega L, Señaris A, Montés-Micó R. Quality of vision with the Acri.Twin asymmetric diffractive bifocal intraocular lens system. J Cataract Refract Surg. 2007;33:197–202.

    Article  Google Scholar 

  9. Fernández-Vega L, Alfonso JF, Baamonde MB, Montés-Micó R. Symmetric bilateral implantation of a distance dominance diffractive bifocal intraocular lens. J Cataract Refract Surg. 2007;33:1913–7.

    Article  Google Scholar 

  10. Alfonso JF, Fernández-Vega L, Blazquez J, Montés-Micó R. Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses. J Cataract Refract Surg. 2009;35:672–6.

    Article  Google Scholar 

  11. Alió JL, Plaza A, Piñero D, Amparo F, Jimenez R, Rodriguez-Prats JL, Javaloy J, Pongo V. Optical analysis, reading performance and quality of life evaluation after implantation of the Acri.Lisa 366D diffractive multifocal intraocular lens. J Cataract Refract Surg. 2011;37:27–37.

    Article  Google Scholar 

  12. Alió JL, Elkady B, Ortiz D, Bernabeu G. Microincision multifocal intraocular lens with and without a capsular tension ring: optical quality and clinical outcomes. J Cataract Refract Surg. 2008;34:1468–75.

    Article  Google Scholar 

  13. Alió JL, Piñero DP, Plaza-Puche AB, Amparo F, Jiménez R, Rodríguez-Prats JL, Javaloy J. Visual and optical performance with two different diffractive multifocal intraocular lenses compared to a monofocal lens. J Refract Surg. 2011;27:570–81.

    Article  Google Scholar 

  14. Alió JL, Radner W, Plaza-Puche AB, Ortiz D, Neipp MC, Quiles MJ, Rodríguez-Marín J. Design of short Spanish sentences for measuring reading performance: Radner Vissum test. J Cataract Refract Surg. 2008;34:638–42.

    Article  Google Scholar 

  15. Radner W, Obermayer W, Richter-Müksch S, Willinger U, Velikay-Parel M, Eisenwort B. Reliability and validity of short German sentences for measuring reading speed. Graefe Arch Klin Ophthalmol. 2002;240:461–7.

    Article  Google Scholar 

  16. Castillo-Gómez A, Carmona-González D, Martínez-de-la-Casa JM, et al. Evaluation of image quality after implantation of 2 diffractive multifocal intraocular lens models. J Cataract Refract Surg. 2009;35:1244–50.

    Article  Google Scholar 

  17. Alfonso JF, Madrid-Costa D, Poo-López A, Montés-Micó R. Visual quality after diffractive intraocular lens implantation in eyes with previous myopic laser in situ keratomileusis. J Cataract Refract Surg. 2008;34:1848–54.

    Article  Google Scholar 

  18. Alfonso JF, Fernández-Vega L, Señaris A, Montés-Micó R. Prospective study of the Acri-Lisa bifocal intraocular lens. J Cataract Refract Surg. 2007;33:1930–5.

    Article  Google Scholar 

  19. Maurino V, Allan BD, Rubin GS, Bunce C, **ng W, Findl O, Moorfields IOL Study Group. Quality of vision after bilateral multifocal intraocular lens implantation: a randomized trial – AT LISA 809M versus AcrySof ReSTOR SN6AD1. Ophthalmology. 2015;122:700–10.

    Article  Google Scholar 

  20. Alió JL, Kaymak H, Breyer D, Cochener B, Plaza-Puche AB. Quality of life related variables measured for three multifocal diffractive intraocular lenses: a prospective randomised clinical trial. Clin Exp Ophthalmol. 2018;46:380–8.

    Article  Google Scholar 

  21. Plaza-Puche AB, Alio JL, Sala E, Mojzis P. Impact of low mesopic contrast sensitivity outcomes in different types of modern multifocal intraocular lenses. Eur J Ophthalmol. 2016;26:612–7.

    Article  Google Scholar 

  22. Plaza-Puche AB, Alio JL. Analysis of defocus curves of different modern multifocal intraocular lenses. Eur J Ophthalmol. 2016;26:412–7.

    Article  Google Scholar 

  23. Kaymak H, Breyer D, Alió JL, Cochener B. Visual performance with bifocal and trifocal diffractive intraocular lenses: a prospective three-armed randomized multicenter clinical trial. J Refract Surg. 2017;33:655–62.

    Article  Google Scholar 

  24. Alio JL, Schimchak P, Montés-Micó R, Galal A. Retinal image quality after microincision intraocular lens implantation. J Cataract Refract Surg. 2005;31:1557–60.

    Article  Google Scholar 

  25. Castillo-Gómez A, Carmona-González D, Martínez-de-la-Casa JM, Palomino-Bautista C, García-Feijoo J. Evaluation of image quality after implantation of 2 diffractive multifocal intraocular lens models. J Cataract Refract Surg. 2009;35:1244–50.

    Article  Google Scholar 

  26. McAlinden C, Pesudovs K, Moore JE. The development of an instrument to measure quality of vision: the Quality of Vision (QoV) questionnaire. Invest Ophthalmol Vis Sci. 2010;51:5537–45.

    Article  Google Scholar 

Download references

Compliance with Ethical Requirements

Jorge L. Alió and Ana B. Plaza-Puche declare that they have no conflict of interest. All procedures followed were in accordance with the ethical standards of the responsible committee on human experimentation (institutional and national) and with the Helsinki Declaration of 1975, as revised in 2000. Informed consent was obtained from all patients for being included in the study. No animal studies were carried out by the authors for this article.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jorge L. Alió .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Plaza-Puche, A.B., Alió, J.L. (2019). Multifocal Intraocular Lenses: AT LISA 809 Diffractive Bifocal Intraocular Lens. In: Alió, J., Pikkel, J. (eds) Multifocal Intraocular Lenses. Essentials in Ophthalmology. Springer, Cham. https://doi.org/10.1007/978-3-030-21282-7_15

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-21282-7_15

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-21281-0

  • Online ISBN: 978-3-030-21282-7

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics

Navigation