Search
Search Results
-
Prediction of distal tibial articular extension in tibial shaft fractures: both posterior malleolar fracture and non posterior malleolar fracture intra-articular extension
BackgroundMultiple authors have highlighted the increased incidence of occult posterior malleolar fractures (PMFs) with spiral tibial shaft...
-
Regional anesthesia improves inpatient but not outpatient opioid demand in tibial shaft fracture surgery
BackgroundPatients undergoing operative treatment of tibial shaft fractures have considerable pain largely managed with opioids. Regional anesthesia...
-
Risk factors for delayed return to work following tibial shaft fracture surgery
PurposeTo determine when patients return to work following operative repair of tibial shaft fractures (TSF) and what risk factors are associated with...
-
Intra-articular fracture patterns associated with tibial shaft fractures: more than just the posterior malleolus
BackgroundThe association of tibial shaft fractures (TSFs) with posterior malleolar fractures is well described. The purpose of this study was to...
-
Plain X-ray is insufficient for correct diagnosis of tibial shaft spiral fractures: a prospective trial
PurposeTibial shaft spiral fractures and fractures of the distal third of the tibia (AO:42A/B/C and 43A) frequently occur with non-displaced...
-
Assessing the effectiveness of intramedullary nailing for tibial shaft fractures in a low-income setting: a prospective study in Yemen
BackgroundTibial shaft fractures are common injuries that can be treated with various methods, including interlocked intramedullary nail (IMN)....
-
Paediatric tibial shaft fractures: an instructional review for the FRCS exam
This instructional review presents the literature and guidelines relevant to the classification, management and prognosis of paediatric tibial shaft...
-
Fracture obliquity angle and distance from plafond: novel radiographic predictors of posterior malleolar involvement in tibial shaft fractures
BackgroundThe purpose of this study was to identify specific radiographic parameters that are predictive of associated PM fractures in TSFs.
... -
Suprapatellar intramedullary nail combined with screw fixation has comparable surgical outcomes to minimally invasive locking plate fixation in ipsilateral tibial plateau and shaft fractures
PurposeTo compare union rate, union time, alignment, and complication rate in ipsilateral tibia plateau and shaft fractures treated via suprapatellar...
-
Suprapatellar intramedullary nailing of tibial shaft fractures in pregnancy. A report of two cases
BackgroundTreatment of closed tibial shaft fractures in the 3 rd trimester of pregnancy is controversial. Since there are few case reports published...
-
Imaging risk factors for predicting postoperative complications of intramedullary nailing for tibial fracture
ObjectiveThe objective of this study was to analyze the ratio of fracture site diameter to tibial isthmus diameter (TFI ratio) as a predictor of...
-
Multiplanar fracture reducer versus manual traction in the treatment of tibial shaft fractures with intramedullary nails
ObjectThe purpose of this study was to propose a new traction device, a multiplanar fracture reducer (MFR), for the treatment of tibial shaft...
-
Comparison of mini-open reduction and autologous bone grafting with closed reduction and intramedullary device insertion for tibial shaft fractures: a retrospective study
BackgroundWe compared the clinical efficacy of mini-open reduction and autologous bone grafting ( G M ) and closed reduction ( G C ) using intramedullary...
-
External fixation versus intramedullary nailing for the management of open tibial fracture: meta-analysis of randomized controlled trials
AimTibial shaft fractures are the most common type of long-bone fractures. External fixation (EF) and intramedullary nailing (IMN) are widely used...
-
Suprapatellar tibial fracture nailing is associated with lower rate for acute compartment syndrome and the need for fasciotomy compared with the infrapatellar approach
BackgroundIntramedullary tibial nailing (IMN) is the gold standard for stabilizing tibial shaft fractures. IMN can be performed through an infra- or...
-
Development of patient-specific osteosynthesis including 3D-printed drilling guides for medial tibial plateau fracture surgery
PurposeA substantial proportion of conventional tibial plateau plates have a poor fit, which may result in suboptimal fracture reduction due to...
-
Effectiveness of Nail Dynamization in Delayed Union of Tibial Shaft Fractures: Relationship Between Fracture Morphology, Callus Diameter, and Union Rates
ObjectiveDynamization has already been described as a secondary intervention for delay unions of tibial shaft fractures treated with intramedullary...
-
The absence of reporting standards and a lack of objective, performance-based outcomes following intramedullary nailing of tibial shaft fractures: findings from a sco** review into 179 articles
PurposeThis sco** review was conducted to summarise the outcome tools reported in the assessment of tibial shaft fractures treated with...
-
Surgical treatment of pycnodysostosis associated with pathological tibial fracture
BackgroundPycnodysostosis is a rare autosomal recessive lysosomal disorder of bone characterized by diffuse skeletal condensation with thickening of...
-
Native tibia valga: a potential source of varus malreduction during intramedullary tibial nail fixation of tibial shaft fractures
PurposeTo determine the effect of native tibia valga on intramedullary nail (IMN) fixation of tibial shaft fractures.
MethodsRetrospective...