We are improving our search experience. To check which content you have full access to, or for advanced search, go back to the old search.

Search

Please fill in this field.

Search Results

Showing 1-20 of 10,000 results
  1. 3D printing for orbital volume anatomical measurement

    Purpose

    The aim was to develop a method for reproducible orbital volume (OV) measurement in vivo based on 3D printing.

    Methods

    Twelve orbits were...

    Nolwenn Piot, Florent Barry, ... Romain Nicot in Surgical and Radiologic Anatomy
    Article 02 July 2022
  2. Development of a 3D-printed neonatal congenital diaphragmatic hernia model and standardisation of intra-operative measurement

    Introduction

    Three-dimensional (3D) printing is frequently used for surgical simulation and training, however, no widely available model exists for...

    George S. Bethell, Mary Patrice Eastwood, ... Jonathan J. Neville in Pediatric Surgery International
    Article Open access 26 December 2023
  3. Assessment of Three Breast Volume Measurement Techniques: Single Marking, MRI and Crisalix 3D Software®

    Introduction

    Measuring breast volume is important to obtain satisfactory breast surgery results, and many techniques are used for this purpose. Thus,...

    Aleksandra Markovic, Salustiano Gomes de Pinho Pessoa, ... Diego Ariel de Lima in Aesthetic Plastic Surgery
    Article 19 June 2023
  4. Diagnostic value of 3D volume measurement of central pulmonary artery based on CTPA images in the pulmonary hypertension

    Background

    This retrospective study aims to evaluate the diagnostic value of volume measurement of central pulmonary arteries using computer...

    Wanwan Zhao, Jialing Guo, ... Cong Shen in BMC Medical Imaging
    Article Open access 13 December 2023
  5. Association Between Automated 3D Measurement of Coronary Luminal Narrowing and Risk of Future Myocardial Infarction

    This study focuses on identifying anatomical markers with predictive capacity for long-term myocardial infarction (MI) in focal coronary artery...

    Alessandro Candreva, Maurizio Lodi Rizzini, ... Umberto Morbiducci in Journal of Cardiovascular Translational Research
    Article Open access 01 March 2024
  6. Accuracy, repeatability, and reproducibility of T1 and T2 relaxation times measurement by 3D magnetic resonance fingerprinting with different dictionary resolutions

    Objectives

    To assess the accuracy, repeatability, and reproducibility of T 1 and T 2 relaxation time measurements by three-dimensional magnetic...

    Krishna Pandu Wicaksono, Yasutaka Fushimi, ... Yuji Nakamoto in European Radiology
    Article Open access 24 November 2022
  7. Automated measurement of total kidney volume from 3D ultrasound images of patients affected by polycystic kidney disease and comparison to MR measurements

    Purpose

    Total kidney volume (TKV) is the most important imaging biomarker for quantifying the severity of autosomal-dominant polycystic kidney disease...

    Jaidip M. Jagtap, Adriana V. Gregory, ... Timothy L. Kline in Abdominal Radiology
    Article Open access 27 April 2022
  8. Consistency of 3D femoral torsion measurement from MRI compared to CT gold standard

    Background

    Several hip and knee pathologies are associated with aberrant femoral torsion. Diagnostic workup includes computed tomography (CT) and...

    Thomas Vincent Häller, Pascal Schenk, ... Patrick Oliver Zingg in BMC Musculoskeletal Disorders
    Article Open access 28 August 2021
  9. Comparison of Conventional Methods for Bowel Length Measurement in Laparoscopic Surgery to a Novel Computer-Assisted 3D Measurement System

    Purpose

    Accurate laparoscopic bowel length measurement (LBLM), which is used primarily in metabolic surgery, remains a challenge. This study aims to...

    Martin Wagner, Benjamin F. B. Mayer, ... Beat-Peter Müller-Stich in Obesity Surgery
    Article Open access 30 July 2021
  10. Automated measurement of alpha angle on 3D-magnetic resonance imaging in femoroacetabular im**ement hips: a pilot study

    Background

    Femoroacetabular im**ement (FAI) syndrome is an established pre-osteoarthritic condition. Diagnosis is based on both clinical and...

    Nastassja Pamela Ewertowski, Christoph Schleich, ... Bernd Bittersohl in Journal of Orthopaedic Surgery and Research
    Article Open access 30 July 2022
  11. Comparison of pelvic incidence measurement using lateral x-ray, standard ct versus ct with 3d reconstruction

    Purpose

    Pelvic incidence (PI) is a position independent parameter used to quantify spinopelvic sagittal balance. PI is generally measured on lateral...

    Carol M. Lee, Raymond W. Liu in European Spine Journal
    Article 06 November 2021
  12. The quest for optimal femoral torsion angle measurements: a comparative advanced 3D study defining the femoral neck axis

    Purpose

    There is high variability in femoral torsion, measured on two-dimensional (2D) computed tomography (CT) scans. The aim of this study was to...

    Bert Van fraeyenhove, Jeroen C. F. Verhaegen, ... Peter Verdonk in Journal of Experimental Orthopaedics
    Article Open access 18 December 2023
  13. Development of 3D printed patient-specific skull implants based on 3d surface scans

    Sometimes cranioplasty is necessary to reconstruct skull bone defects after a neurosurgical operation. If an autologous bone is unavailable,...

    Fabian Kropla, Dirk Winkler, ... Ronny Grunert in 3D Printing in Medicine
    Article Open access 30 June 2023
  14. How to measure children’s feet: 3D foot scanning compared with established 2D manual or digital methods

    Background

    In infants and young children, a wide heterogeneity of foot shape is typical. Therefore, children, who are additionally influenced by rapid...

    Juliane Mueller, Monika Richter, ... Steffen Mueller in Journal of Foot and Ankle Research
    Article Open access 15 April 2023
  15. The clinical value of preoperative 3D planning and 3D surgical guides for Imhäuser osteotomy in slipped capital femoral epipysis: a retrospective study

    Background

    Accurate repositioning of the femoral head in patients with Slipped Capital Femoral Epiphysis (SCFE) undergoing Imhäuser osteotomy is very...

    Vera Lagerburg, Michelle van den Boorn, ... Melinda M. E. H. Witbreuk in 3D Printing in Medicine
    Article Open access 01 March 2024
  16. Development of a 3D-printed nuchal translucency model: a pilot study for prenatal ultrasound training

    Background

    We used two 3D ultrasound volumes of fetal heads at 13 weeks to create live-size 3D-printed phantoms with a view to training or assessment...

    Florian Recker, Laura Remmersmann, ... Valentin S. Schäfer in Archives of Gynecology and Obstetrics
    Article Open access 25 May 2024
  17. Validation study of new left atrial appendage closure device measurement by two-dimensional and three-dimensional transesophageal echocardiography

    Background

    In left atrial appendage closure using WATCHMAN FLX, accurate device measurement by transesophageal echocardiography (TEE) is important. We...

    Sachiyo Ono, Takeshi Maruo, ... Kazushige Kadota in Journal of Echocardiography
    Article 29 August 2023
  18. 3D-MRI versus 3D-CT in the evaluation of glenoid deformity in glenohumeral arthritis using Dixon 3D FLASH sequence

    Objective

    To compare MRI with 3D reconstructions and 3D-CT with respect to assessment of glenoid wear in osteoarthritic shoulders.

    Methods ...
    Yoav Rosenthal, Mohammad Samim, ... Mandeep S. Virk in Skeletal Radiology
    Article 23 June 2022
  19. Deep learning-based super-resolution of structural brain MRI at 1.5 T: application to quantitative volume measurement

    Objective

    This study investigated the feasibility of using deep learning-based super-resolution (DL-SR) technique on low-resolution (LR) images to...

    Atita Suwannasak, Salita Angkurawaranon, ... Uten Yarach in Magnetic Resonance Materials in Physics, Biology and Medicine
    Article 17 May 2024
Did you find what you were looking for? Share feedback.