Search
Search Results
-
Arthroscopic-assisted reduction and internal fixation for complex tibial plateau fracture: radiographic and clinical outcomes with 2- to 15-year follow-up
BackgroundTo investigate the radiologic and prognostic outcomes after using arthroscopic-assisted reduction and internal fixation (ARIF) in complex...
-
Fracture map** of adult femoral neck fractures with three dimensional computed tomography
PurposeFemoral neck fractures (FNFs) are a commonly encountered injury in orthopaedic practice. It is essential that surgeons recognize specific...
-
Design and Development of a Novel 3-D Printed External Fixation Device for Fracture Stabilization
BackgroundAn external fixator is an orthopaedic device used to stabilize long bone fractures after high energy trauma. These devices are external to...
-
Curative effect of external fixation combined with kirschner wire versus hollow screw in the treatment of first metacarpal bone base fracture
PurposeThis study was conducted aimed at comparing the curative effect of external fixation combined with Kirschner wire fixation versus hollow screw...
-
Comparison of buttress plate and cannulated screw in the treatment of anteromedial coronoid fracture with elbow posteromedial rotatory instability
PurposeThe purpose of this study is to compare the effect of buttress plate and cannulated screw in the treatment of anteromedial coronoid fracture...
-
The effect of integrity of lesser tuberosity-medial calcar on postoperative outcome in the proximal humeral fracture
BackgroundIn proximal humeral fractures, the medial calcar is often considered an important stabilizing structure. When the medial calcar is...
-
Calcaneal fracture maps and their determinants
BackgroundCalcaneal fractures are associated with numerous complications and a poor prognosis with significant long-term quality-of-life issues,...
-
Postoperative 3D computed tomographic evaluation of 92 calcaneal fracture reduction using the sinus tarsi technique and fixation with 3.5 mm cortical screws
BackgroundFixation of calcaneus through the sinus tarsi approach is increasingly popular due to the lower rate of wound complications. The use of...
-
Incidence of bony Bankart lesions in Sweden: a study of 790 cases from the Swedish fracture register
BackgroundA bony Bankart lesion directly affects the stability of the shoulder by reducing the glenoid joint-contact area. The aim of this study was...
-
Dual mini-fragment plate fixation of midshaft clavicle fractures is biomechanically equivalent to anatomic pre-contoured plating
ObjectivesTo biomechanically compare the stiffness of midshaft synthetic clavicle osteotomies fixed with either superior anatomic pre-contoured...
-
The pivot fracture: an unusual tibial plateau fracture found in association with acute ACL injury
Tibial plateau fractures are common fractures which are often associated with concurrent soft tissue injury and for which accurate preoperative...
-
Subcutaneous emphysema and pneumomediastinum following orbital blowout pathological fracture in a cat with nasal lymphoma: a case report
BackgroundSubcutaneous emphysema and pneumomediastinum are rare complications associated with orbital blowout pathological fracture.
Case presentation ... -
Delayed-onset radiculopathy caused by a retropulsed bone fragment after percutaneous kyphoplasty: report of four cases and literature review
BackgroundVertebral compression fractures caused by osteoporosis are common in elderly patients and are often encountered by clinical physicians....
-
Outcomes of embedded rafting k-wire technique for intermediate articular fragment fixation in comminuted olecranon fractures
BackgroundSeverely comminuted olecranon fractures are challenging injuries. Commonly used tension band wiring exerts excessive compressive forces...
-
Simulated full weight bearing following posterior column acetabular fracture fixation: a biomechanical comparability study
PurposeThe incidence of acetabular fractures (AFs) is increasing in all industrial nations, with posterior column fractures (PCFs) accounting for...
-
A new technique of intramedullary elastic reduction of the “de-sharpened” Kirschner wire for the treatment of Gartland type III posterolateral displaced supracondylar fracture of the humerus in children
ObjectiveTo compare the clinical effects of intramedullary elastic reduction of the “de-sharpened Kirschner wire and traditional three-dimensional...
-
Tuberosity refixation improves functional outcome following primary reverse shoulder arthroplasty in proximal humeral fracture
IntroductionThe purpose of this prospective study was to examine clinical results of tuberosity refixation in RSA for the treatment of displaced PHF...
-
The double-plate fixation technique prevents varus collapse in AO type C3 supra-intercondylar fracture of the distal femur
IntroductionVarus collapse followed by osteosynthesis for distal femoral fractures with conventional implants has been well documented but is seldom...
-
Comparative analysis of tension band wiring and hook plate fixation in ulnar styloid fractures: a focus on fracture type
IntroductionVarious surgical techniques for ulnar styloid fractures (USFs) fixation have recently been developed, the actual clinical outcomes have...
-
Comparison of different intraoperative reduction monitoring methods in a cadaveric intraarticular calcaneal fracture model: 3D scan vs arthroscopy vs nanoscopy
AimsVisualization of the subtalar joint surface in surgical management of calcaneal factures remains a big challenge and anatomic reduction of the...