Search
Search Results
-
The geriatric distal femur fracture: nail, plate or both?
Surgical fixation of distal femur fractures in geriatric patients is an evolving topic. Unlike hip fractures, treatment strategies for distal femur...
-
Festigkeit der Konusverbindung modularer Revisionshüftschäfte
IntroductionIn revision surgery, modular implant components allow the surgeon to tailor the characteristics of the implant to the bone situation....
-
Operative treatment outcomes of anterior sternoclavicular joint dislocation using two experimental methods - an acromioclavicular joint hook plate versus a locking plate: a retrospective study
BackgroundWe aimed to compare the intraoperative and early postoperative clinical outcomes of using an acromioclavicular joint hook plate (AJHP)...
-
Implant-dependent behavior of tunnel widening and clavicular button migration after arthroscopic-assisted treatment of acromioclavicular joint instabilities
IntroductionDespite ongoing discussions for the previous few decades, there is still no consensus regarding the optimal surgical technique for...
-
Is TKA femoral implant stability improved by pressure applied cement? a comparison of 2 cementing techniques
BackgroundThe majority of knee endoprostheses are cemented. In an earlier study the effects of different cementing techniques on cement penetration...
-
Elliptical and spherical heads show similar obligate glenohumeral translation during axial rotation in total shoulder arthroplasty
BackgroundElliptical shape humeral head prostheses have been recently proposed to reflect a more anatomic shoulder replacement. However, its effect...
-
15-year survivorship of a unique dual-modular femoral stem in primary hip arthroplasty
BackgroundHip offset, version, and length are interdependent femoral variables which determine stability and leg length. Balancing these competing...
-
Fixators dynamization for delayed union and non-union of femur and tibial fractures: a review of techniques, timing and influence factors
The optimal balance between mechanical environment and biological factors is crucial for successful bone healing, as they synergistically affect bone...
-
Comparison of medial tibiofemoral joint mechanics between all-suture anchors and transtibial pullout technique for posterior medial meniscal root tears
BackgroundThe posterior medial meniscal root tear (PMMRT) seriously impacts the tibiofemoral joint biomechanics. Two available techniques for PMMRT...
-
Lumbar vertebral canal stenosis due to marked bone overgrowth after routine hemilaminectomy in a dog
BackgroundBone overgrowth after decompressive surgery for lumbar stenosis resulting in recurrence of neurological signs has not been reported in...
-
Microinstability characterised by small and easily overlooked anterior labral or Hill–Sachs lesions can be managed with arthroscopic anterior labral repair
PurposeSome young individuals present with shoulder pain without a definite history or complaint of instability. However, careful history taking,...
-
Epiphyseal fixation in revision total knee arthroplasty: a comparison between trabecular metal and titanium augments
IntroductionThe purpose of this retrospective study was to compare the medium-term clinical and radiographic outcomes of two series of patients...
-
Wear debris in metal-on-metal bearings and modular junctions
Metal-on-metal (MoM) bearing hip arthroplasty saw increasing utilization and peaked in the 1990s and early 2000s. Although the linear and volumetric...
-
Nailing of proximal ulna fractures: biomechanical comparison of a new locked nail with angular stable plating
PurposeProximal ulna fractures are common injuries and frequently treated with angular stable plating. This surgical option shows good functional...
-
PEEK Interference Screws Show Significant Tunnel Enlargement After ACL Reconstruction and is Comparable to Adjustable-Length Loop Cortical Button Fixation
BackgroundIt is unclear whether the use of polyetheretherketone (PEEK) interference screws for anterior cruciate ligament (ACL) reconstruction leads...
-
Comparison of the clinical outcomes between proximal femoral nail anti-rotation with cement enhancement and hemiarthroplasty among elderly osteoporotic patients with intertrochanteric fracture
BackgroundThe proximal femoral nail anti-rotation (PFNA) with cement enhancement enhances the anchorage ability of internal fixation in elderly with...
-
Biomechanical effect of endplate defects on the intermediate vertebral bone in consecutive two-level anterior cervical discectomy and fusion: a finite element analysis
BackgroundIntermediate vertebral collapse is a newly discovered complication of consecutive two-level anterior cervical discectomy and fusion (ACDF)....
-
Anterior cruciate ligament femoral side retained stump technique reduces enlargement of the femoral bone tunnel after anterior cruciate ligament reconstruction
BackgroundEnlargement of the bone tunnel has become an unavoidable early complication after anterior cruciate ligament (ACL) reconstruction, whether...
-
A case-driven hypothesis for multi-stage crack growth mechanism in fourth-generation ceramic head fracture
BackgroundCeramic bearings are used in total hip arthroplasty due to their excellent wear behaviour and biocompatibility. The major concern related...
-
Stress distributions of the short stem and the tapered wedge stem at different alignments: a finite element analysis study
BackgroundThe mechanical effects of stem length reduction and stem alignment on the surrounding femur remain unknown. This study directly compared...