-
Article
Open AccessSCMR expert consensus statement for cardiovascular magnetic resonance of acquired and non-structural pediatric heart disease
Cardiovascular magnetic resonance (CMR) is widely used for diagnostic imaging in the pediatric population. In addition to structural congenital heart disease (CHD), for which published guidelines are available...
-
Article
Evaluation of self-calibrated non-linear phase-contrast correction in pediatric and congenital cardiovascular magnetic resonance imaging
The need for background error correction in phase-contrast flow analysis has historically posed a challenge in cardiac magnetic resonance (MR) imaging. While previous studies have shown that phantom correction...
-
Article
Open AccessNonlinear self-calibrated phase contrast correction in pediatric and congenital cardiovascular magnetic resonance imaging
-
Article
Open AccessCardiovascular magnetic resonance techniques and findings in children with myocarditis: a multicenter retrospective study
Cardiovascular magnetic resonance (CMR) is increasingly used to diagnose myocarditis in adults but its use in children is not well-established. We sought to describe the presentation, CMR protocol and findings...
-
Article
Open AccessCMR techniques and findings in children with myocarditis: a multicenter retrospective study
-
Article
Open AccessProgression of right ventricular dilation in repaired tetralogy of fallot
-
Article
Chamber and Vessel Quantification in Pediatric Echocardiography: What Do the Guidelines Teach Us?
The American Society of Echocardiography has recently published guidelines for chamber and vessel quantification during a pediatric echocardiogram. Because the sizes of cardiovascular structures increase with ...
-
Article
Repeatability of cardiac-MRI-measured right ventricular size and function in congenital heart disease
The measurement error for right ventricular (RV) size and function assessed by cardiac MRI (CMRI) in congenital heart disease has not been fully characterized. As CMRI parameters are being increasingly utilize...
-
Article
Open AccessCorrection of phase offset errors in cardiovascular magnetic resonance using background subtraction from stationary tissue
-
Article
Open AccessBaseline correction of phase-contrast images in congenital cardiovascular magnetic resonance
One potential source of error in phase contrast (PC) congenital CMR flow measurements is caused by phase offsets due to local non-compensated eddy currents. Phantom correction of these phase offset errors has ...
-
Article
Open AccessBaseline correction of phase-contrast images in congenital Cardiac Magnetic Resonance Imaging
-
Article
Open Access1058 The extent of tricuspid valve septal displacement adversely affects right ventricular function in Ebstein anomaly: a cardiac MRI study
-
Article
Accuracy of guideline recommendations for two-dimensional quantification of the right ventricle by echocardiography
Background The accuracy of the guidelines of the American Society of Echocardiography (ASE) for the two-dimensional (2D) quantitative assessment of right ventricular (RV) size and function has not been evaluated ...