Abstract
Recently, the applicability of Penning trap mass spectrometry has been extended to nuclides with a half-life of less than one second. The mass of 33Ar(T 1/2 = 174 ms) was measured using the ISOLTRAP spectrometer with an accuracy of 4.2 keV. This measurement provided a stringent test of the Isobaric Multiplet Mass Equation (IMME) at mass number A = 33 and isospin T = 3/2. The fast measurement cycle that shows the way to other measurements of very-short-lived nuclides is presented. Furthermore, the results of the IMME test are displayed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Adelberger, E. G. et al., Phys. Rev. Lett. 83 (1999), 1299 and 3101.
Kugler, E. et al., Nucl. Instrum. Methods B 70 (1992), 41–49.
Herfurth, F. et al., A linear radiofrequency ion trap for accumulation, bunching, and emittance improvement of radioactive ion beams, Nucl lustrum. Methods A (2000), accepted; also CERN preprint: CERN-EP/2000–062.
Raimbault-Hartmann, H. et al., Nucl. Instrum. Methods B 126 (1997), 378.
Bollen, G. et al., Nucl. Instrum. Methods A 368 (1996), 675–697.
Bollen, G. et al., this issue, 215.
Audi, G. and Wapstra, A. H., Nuclear Phys. A 595 (1995), 1.
Carlberg, C. et al., 1999.
Mohr, P. J. and Taylor, B. N., Rev. Modem Phys. 72 (2000), 351; 1998 CODATA values.
Beck, D. et al., Nucl. Instrum. Methods B 126 (1997), 374.
Nann, H. et al., Phys. Rev. C 9 (1974), 1848.
Herfurth, F. et al., submitted to Phys. Rev. Lett; also CERN preprint: CERN-EP/2000–142.
Britz, J., Pape, A. and Antony, M. S., At. Data Nucl Data Tables 69 (1998), 125–159.
Henley, E. M. and Lacy, C. E., Phys. Rev. 184 (1969), 1228.
Jänecke, J., Nuclear Phys. A 128 (1969), 632.
Bertsch, G. and Kahana, S., Phys. Lett. B 33 (1970), 193.
Author information
Authors and Affiliations
Consortia
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2001 Kluwer Academic Publishers
About this paper
Cite this paper
Herfurth, F. et al. (2001). Towards Shorter-Lived Nuclides in ISOLTRAP Mass Measurements. In: Lunney, D., Audi, G., Kluge, HJ. (eds) Atomic Physics at Accelerators: Mass Spectrometry. Springer, Dordrecht. https://doi.org/10.1007/978-94-015-1270-1_27
Download citation
DOI: https://doi.org/10.1007/978-94-015-1270-1_27
Publisher Name: Springer, Dordrecht
Print ISBN: 978-90-481-5825-6
Online ISBN: 978-94-015-1270-1
eBook Packages: Springer Book Archive