Abstract
Purpose: Obstructive Sleep Apnea(OSA) is an airway obstructed during sleep, due to intermittent respiratory arrest disease. Flow limitation is an important symptom of OSA, but the method of detecting flow limitation was not clear now. Materials: Signal source record of clinical patients with Polysomnography (PSG), Capture identified as RERA respiratory flow different categories 47 cases respiratory flow signal, 10 cases marked normal, 37 cases marked flow limitation. Method: Use 3 methods to Detect. (1)Flattening index (F.I) feature: Accepted standards for the majority of studies, the mean deviation of the inspiratory wave from the reference amplitude, for a middle portion of the wave are calculated. Weight F.I by F.I is based on the weighted improvements. (2)Value Weight: Weighted above average of inspiratory waveform data. (3)Time Weight: Weighted after the middle of inspiratory waveform data. Results: Comparison 4 different detection methods analysis 47 cases of respiratory flow signal. The results of measurement, F.I could correctly distinguish the 41 cases, the error rate is about 12%. Value Weight could correctly distinguish the 42 cases, the error rate is about 10%. Time Weight could correctly distinguish the 41 cases, the error rate is about 12%. Conclusions: Use described above 4 methods detection can be achieved correct rate of 80% or more. The value weight has the lowest error rate, Can clearly distinguishing severe and mild obstructive, is the best detection of 4 methods. The ability of F.I to distinguish mild and severe slightly inferior to Value Weight, but enhanced slightly discernment. The time weight is particularly suitable for distinguishing M shaped or square shaped respiratory patters indicative of partially obstructed airways.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this paper
Cite this paper
Lin, K.P. et al. (2014). Feature Evaluation of Flow Limitation in Obstructive Sleep Apnea Cases. In: Goh, J. (eds) The 15th International Conference on Biomedical Engineering. IFMBE Proceedings, vol 43. Springer, Cham. https://doi.org/10.1007/978-3-319-02913-9_140
Download citation
DOI: https://doi.org/10.1007/978-3-319-02913-9_140
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-02912-2
Online ISBN: 978-3-319-02913-9
eBook Packages: EngineeringEngineering (R0)