Abstract
There are various surgical methods for tracheoesophageal fistula; however, there is presently no unified standard. Based on the magnetic compression technique, we designed a novel method for the treatment of tracheoesophageal fistula. The purpose of this study was to verify its feasibility in an animal experiment. Six beagle dogs underwent surgical repair after constructing a tracheoesophageal fistula model. After the tracheal and esophageal spaces were freed during the operation, two magnets were used to clamp the fistula. The operation time, intraoperative blood loss, postoperative complications, and wound healing were monitored. Samples were obtained 14 days after the operation, and fistula repair was observed. The tracheoesophageal fistula repair operation was successfully completed for all six beagles. The average operation time was 23.67 ± 4.50 min. The average intraoperative blood loss was less than 10 mL. One dog had a postoperative wound infection, and the rest had no postoperative complications. The wound healed well. In all dogs, after specimen collection, it was observed that the fistula was successfully closed and the mucosal layer was smooth and flat. Histological observation showed that the anastomosis was slightly inflamed, the mucosal layer and surrounding tissues were arranged neatly, and the structure was slightly disordered. Magnetic compression technique can be effectively used to repair tracheoesophageal fistula, shorten the operation time, and simplify the operation procedure, and thus, it has the potential for clinical application.
Similar content being viewed by others
Introduction
Tracheoesophageal fistula (TEF) is a pathological passage formed between the trachea and esophagus. It can be caused by congenital malformation, tumors, surgery, and trauma, among other causes. Congenital TEF mostly accompanies esophageal atresia, which occurs in 1/3000–5000 births, and only 4% of congenital TEF cases show an isolated H-type fistula (i.e., TEF without esophageal atresia)1. TEF develops in 5–15% of patients with esophageal cancer2. Although the incidence of TEF is not high, it has a high mortality rate. Current treatments for TEF include endoscopic clip**, patch repair, stent implantation, and surgical resection. However, endoscopic clip** and stent implantation do not completely cure the condition and are prone to slippage; they may even cause enlargement and recurrence of the fistula3,4. Surgical resection includes cervicotomy, thoracotomy, and thoracoscopy5,6,7. Although traditional surgical resection can have a curative effect on resectable TEF, the operation is complicated and time-consuming4.
Magnetic compression technique, which is a new anastomosis technology, uses the non-contact force of mutual attraction between magnets to solve various clinical problems8. A smooth anastomosis can be formed by pressing the body tissue, and the operation is simpler than traditional manual anastomosis. At present, the magnetic compression technique has been applied in digestive tract reconstruction8, vascular anastomosis9, and urinary system reconstruction10. Therefore, we designed a TEF repair device based on the magnetic compression technique and verified the safety and feasibility of repairing TEF using this device through experiments.
Material and methods
Ethical statement
The research protocol and all experimental procedures were strictly in accordance with the Guidelines for the Care and Use of Experimental Animals issued by the ** were routinely performed, and the dogs were placed in a supine position. The left femoral vein was cannulated to establish venous access, and saline was slowly instilled. Cefazolin sodium (0.5 g) was intravenously injected 30 min before surgery to prevent infection. We made an incision of about 6 cm along the center of the neck and gradually separated the neck tissue, thus exposing and freeing the trachea and esophagus. The tracheoesophageal space was then separated and TEF was exposed. Then, squeezing magnets were placed on both sides of the fistula such that the long axis of the magnet was in the same direction as the trachea and esophagus. After ensuring that no other important tissues were present between the magnets, the magnets were aligned such that they attracted each other, and the fistula was closed. The neck tissue was sutured layer by layer, and the neck incision was closed. The process of repairing TEF using the magnetic compression technique is shown in Fig. 1.
Postoperative management
All dogs were given intramuscular injection of cefazolin sodium for three consecutive days to prevent infection and pethidine hydrochloride for analgesia for three consecutive days. Experimental animals were given liquid and high-protein diets for the first 5 days after the operation. The healing of the neck wound after the operation was observed daily, and the dogs were monitored for any postoperative complications.
The dogs’ general condition was stable by 14th day postoperatively. Esophagography was first performed before the animals were euthanized, and no contrast agent was developed in the trachea. Then, gastroscopy and bronchoscopy were further performed to confirm fistula closure. Subsequently, all animals were euthanized by a barbiturate overdose (intravenous injection, 60 mg/kg pentobarbital sodium), and the specimens of neck tracheal fistula and esophagus fistula were collected to observe their healing. Then all samples were fixed in 10% formalin. Sections (4–6 µm) were stained with hematoxylin and eosin (HE) and Masson dye for light microscopy.
Statistical analysis
We used SPSS for descriptive statistical analysis of the data. Measurement data conforming to the normal distribution were expressed as mean ± standard deviation (\(\overline{X} \pm s\) ); measurement data with skewed distribution were expressed as M(QR), and count data were expressed as percentages.
Results
Surgical conditions and postoperative complications
All operations were performed by the same team. TEF repairs were successfully completed in all dogs (Fig. 2). The mean operation time was 23.67 ± 4.50 min, and the mean intraoperative blood loss was < 10 mL. Postoperative X-ray fluoroscopy revealed that the magnets were closely attracted to each other, and the TEF was successfully compressed and closed. No vital organs were damaged during the operation, and the magnets did not damage the esophagus wall, tracheal wall, or other important tissues.
Postoperatively, all dogs had poor mental state and poor appetite, which gradually improved after 3–5 days. The anti-infective treatment administered postoperatively continued to improve the dogs’ condition. One of the dogs developed a severe infection in the neck wound, which was treated with a second surgical debridement. The rest of the beagles had no obvious postoperative complications; their neck wound healed well, and the diet returned to normal by 14th day postoperatively. There was no dysphagia or choking after swallowing.
Observation of in vitro specimens
Fourteen days after TEF repair, the fistula was healed well, as confirmed by gastroscopy and bronchoscopy, and no anastomotic leakage or anastomotic stenosis was found in any dog (Fig. 3). Esophagography showed no TEF. Subsequently, we obtained the tissue at the anastomosis site of the trachea and esophagus for further observation. During the dissection, we found that there were marginal tissue adhesions around the anastomosis, and the tracheal and esophageal fistulas were successfully closed. The mucosal surfaces of the esophagus and trachea were observed to be smooth and flat, with no significant difference from the surrounding tissue.
HE staining
The local anastomotic tissue of the trachea and esophagus was isolated, embedded in paraffin, and then frozen-sectioned. It was observed under an optical microscope after HE staining (Fig. 4). On both esophageal and tracheal sides, the mucosal layer has good continuity but is slightly thinner than the surrounding tissues. The tissue structure at the anastomosis was slightly disordered.
Discussion
At present, there are many ways to treat TEF, including endoscopic treatment and surgical resection. The use of titanium forceps to clamp TEF under endoscopy or to block TEF using a stent can effectively relieve the symptoms of patients. The operation trauma is small, and the patients benefit well12,13. In particular, for malignant TEF, endoscopic treatment is the first choice to relieve symptoms14. However, endoscopic clip** therapy cannot effectively solve the larger TEF, and its surgical success rate is only 50%15. Currently, for resectable TEF, surgical resection is the gold standard for clinical treatment, and its success rate can be as high as ~ 90%16,17. The most commonly used surgical repair method in the clinic is the three-layer repair method, which involves repairing the tracheal fistula and esophageal fistula and inserting connective tissue into the tracheoesophageal space to cover the fistula to prevent recurrence. However, this method is time-consuming and traumatic and involves many surgical procedures needed to achieve good results. In this procedure, even a part of the trachea needs to be removed, and the clinical efficacy varies.
Based on the characteristics of TEF, we propose the application of the magnetic compression technique to treat TEF. Cope first reported the technique of anastomosis with magnets18. Subsequently, the use of this technique gradually expanded, and there have been reports on gastrointestinal anastomosis, vascular anastomosis, and fistula repairs using magnets. Regarding the application of magnets in medical technology centers, our team has also conducted a lot of research, which is currently in early stages. In terms of gastrointestinal reconstruction, the anastomotic stoma formed by the magnetic compression technique is smooth and flat with lesser inflammatory reaction than other surgeries (e.g., open surgery), which can reduce the surgical trauma19. Vascular anastomosis with this technique can significantly shorten the operation time. The inferior vena cava anastomosis can be quickly performed using the magnetic compression technique to shorten the operation time of liver transplantation. Compared with manual suture, the operation time using the magnetic compression technique was significantly shorter (27.32 ± 5.12 min vs. 6.25 ± 2.25 min; P < 0.001)9. In terms of fistula repair, the magnetic compression technique can reportedly achieve ideal results in the treatment of rectovaginal fistula20. Our team successfully established a TEF model using a squeezing magnet in the early stage11, which shows that the magnet can effectively squeeze the trachea and esophagus. Accordingly, the present study further explored the use of magnetic compression techniques for the treatment of TEF.
The result shows that the magnetic compression technique can effectively treat TEF. After being compressed by the magnet, the tracheal fistula and the esophageal fistula were healed, and the mucosal surface was smooth and flat. There was no obvious stenosis of the esophagus and trachea, and no anastomotic leakage occurred. Through the magnetic compression technique, ischemic necrosis of the clamped tissue was achieved, and the tissue at both ends of the magnet was healed separately. In this experiment, after separating the TEF, the fistula tract was directly squeezed by a magnet without excision or manual suture, which inevitably shortened the operation time, simplified the operation process, and reduced intraoperative blood loss. As the airway was not open, the surgery could be performed without endotracheal intubation. Notably, once the esophageal and tracheal spaces can be clearly separated, the operation with the magnetic compression technique can be performed with relative ease, which we believe will help reduce the difficulty of TEF surgery.
The magnetic compression technique has shown good results in the treatment of TEF, but it has some limitations. First, in this study, the diameter of the fistula in the animal model of TEF was 1 cm, making it a small TEF, and although no anastomotic stenosis occurred after clip** in this study, the efficacy of this method in treating a larger TEF needs to be further explored. Second, the magnets used in this study required a 6-cm neck incision and were placed by manual coaptation. Whether the magnets can be placed in a more minimally invasive way and more easily should be explored in further research. In addition, in this study, as the beagles were euthanized 14 days after the operation, the survival status of the beagles after the removal of the neck magnet was not observed. Whether the magnetic compression technique is effective in preventing postoperative TEF recurrence needs further investigation.
In this study, we focused more on whether magnetic compression technique can achieve TEF repair. It is meaningful to further optimize the design of surgical protocols only after a good TEF repair effect has been proved. Therefore, in this experiment, the magnet was left in the body and removed 14 days after the operation. We were elated with the results as complete healing of the trachea and esophageal fistulas was observed. We hope that this novel treatment method will attract the interest of our colleagues and that their wisdom and knowledge will help further optimize magnet design and surgical procedures. We believe that if this technology can be clinically applied, we will fix the silicone catheter at one end of the magnet and the other end of the catheter leads out of the neck skin. After the repair of the TEF fistula is completed, the silicone catheter can be pulled to remove the two magnets (just like removing the abdominal drainage tube), thus avoiding the need for a second surgical procedure.
Conclusion
The magnetic compression technique is safe and can repair TEF. It can simplify the operation process, shorten the operation time, and reduce the intraoperative blood loss. No anastomotic stenosis or leakage was noted postoperatively. As a new anastomotic technique, the magnetic compression technique has potential for clinical application in fistula repair.
Data availability
The datasets used and analyzed during the current study available from the corresponding author on reasonable request.
References
Brookes, J. T. et al. H-type congenital tracheoesophageal fistula: University of Iowa experience 1985 to 2005. Ann. Otol. Rhinol. Laryngol. 116, 363–368 (2007).
Ghaffaripour, S., Souki, F. G., Martinez-Lu, K. & Wakim, G. Anesthetic approach for endoscopic repair of acquired tracheoesophageal fistula. Semin. Cardiothorac. Vasc. Anesth. 21, 357–359 (2017).
Sikka, K. et al. Acquired non-malignant cervical trachea-esophageal fistula: A case series. Indian J. Otolaryngol. Head Neck Surg. 71, 286–290 (2019).
Silon, B. et al. Endoscopic management of esophagorespiratory fistulas: a multicenter retrospective study of techniques and outcomes. Dig. Dis. Sci. 62, 424–431 (2017).
Conforti, A. et al. Cervical repair of congenital tracheoesophageal fistula: Complications lurking!. J. Pediatr. Surg. 51, 1623–1626 (2016).
Rozeik, A. E., Elbarbary, M. M., Saleh, A. M., Khodary, A. R. & Al-Ekrashy, M. A. Thoracoscopic versus conventional open repair of tracheoesophageal fistula in neonates: A short-term comparative study. J. Pediatr. Surg. 55, 1854–1859 (2020).
Slater, B. J. & Rothenberg, S. S. Tracheoesophageal fistula. Semin. Pediatr. Surg. 25, 176–178 (2016).
Lu, Q. et al. End-to-end vascular anastomosis using a novel magnetic compression device in rabbits: a preliminary study. Sci. Rep. 10, 5981 (2020).
Cao, Z. et al. Fast and effective nonsuture anastomosis of magnetic artificial blood vessel transplantation for caval reconstruction in canines. Ann. Vasc. Surg. 68, 487–496 (2020).
An, Y. et al. An experimental study of magnetic compression technique for ureterovesical anastomosis in rabbits. Sci. Rep. 13, 1708 (2023).
Gao, Y., Wu, R. Q., Lv, Y. & Yan, X. P. Novel magnetic compression technique for establishment of a canine model of tracheoesophageal fistula. World J. Gastroenterol. 25, 4213–4221 (2019).
Armellini, E. et al. New endoscopic over-the-scope clip system for treatment of a chronic post-surgical tracheoesophageal fistula. Endoscopy 47, E437-438 (2015).
Ke, M., Wu, X. & Zeng, J. The treatment strategy for tracheoesophageal fistula. J. Thorac. Dis. 7, S389-397 (2015).
Spaander, M. C. et al. Esophageal stenting for benign and malignant disease: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline. Endoscopy 48, 939–948 (2016).
Mann, C. et al. Surgical treatment of esophagotracheal and esophagobronchial fistulas. Chirurg 90, 722–730 (2019).
Osho, A., Sachdeva, U., Wright, C. & Muniappan, A. Surgical management of tracheoesophageal fistula. Ann. Cardiothorac. Surg. 7, 314–316 (2018).
Bibas, B. J. et al. Surgical management of benign acquired tracheoesophageal fistulas: A ten-year experience. Ann. Thorac. Surg. 102, 1081–1087 (2016).
Cope, C. Creation of compression gastroenterostomy by means of the oral, percutaneous, or surgical introduction of magnets: Feasibility study in swine. J. Vasc. Interv. Radiol. 6, 539–545 (1995).
Ma, F. et al. A novel magnetic compression technique for small intestinal end-to-side anastomosis in rats. J. Pediatr. Surg. 54, 744–749 (2019).
She, Z. F. et al. Treatment of rectovaginal fistula by magnetic compression. Int. Urogynecol. J. 28, 241–247 (2017).
Acknowledgements
This work was supported by the Institutional Foundation of The First Affiliated Hospital of **’an Jiaotong University (No. 2022MS-07) and the Key Research & Development Program-Social Development of Shaanxi Province of China (No. 2021SF-163). The funders had no role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Author information
Authors and Affiliations
Contributions
Conception and design, Y.X.L., and X.Y.; performed the research and acquired the data, Y.X.L., M.Z., P.L., Z.Z., H.Z. and X.Y.; analyzed the data, Y.X.L. and M.Z.; manuscript writing, Y.X.L. and M.Z.; manuscript revision, Y.L. and X.Y.; final approval of manuscript, all authors.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Li, Y., Zhang, M., Liu, P. et al. Tracheoesophageal fistula treated with magnetic compression technique in canines. Sci Rep 13, 4830 (2023). https://doi.org/10.1038/s41598-023-31903-2
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-023-31903-2
- Springer Nature Limited