Abstract
A multifunctional membrane with biocompatibility, diffusion-limiting effect, and the ability to curtail the responses of an H2O2 electrode to ascorbate and urate was prepared. It was composed of MB, AB, and CTA, where MB is the copolymer of 2-methacryloyloxyethyl phosphorylcholine (MPC) and n-butylmethacrylate (BMA), AB is the copolymer of acrylamide-2-methylpropane sulfonic acid (AMPS) and BMA, CTA is cellulose triacetate. Investigation of the biocompatibility of this membrane showed that, compared with CTA, relatively few platelets bound to it. The membrane was coated onto the working electrode of a needle-type glucose sensor on which immobilized glucose oxidase membrane has been coated. The sensor did not respond to ascorbate and urate at their concentration normally encountered in blood. Its response was not inhibited by metal ions in blood at usual concentration. The sensor exhibited superior thermostability in addition to a rapid response (<90 seconds in batch operation), good reproducibility (RE<5%), good stability (more than 36 hours continuously in heparinized whole blood), and a wide dynamic range (5–650 mg/dl glucose). The sensor was used to determine glucose in serum. The data obtained from the sensor showed good agreement with that from a clinical autoanalyzer (R=0.973).
Similar content being viewed by others
Reference
L. Abe, Bachelor Thesis (Toho University, Japan, 1990).
A. Amine, K. Digua, B. **e, and B. Danielson, Analytical Letters 28, 2275 (1995).
Y. Benmairoha, I. Christie, and P. Vadgama, Analytical Communications 33, 23 (1996).
D.S. Bindra and G.S. Wilson, Anal. Chem. 61, 2566 (1989).
D.S. Bindra, Y. Zhang, and G.S. Wilson, Anal. Chem. 63, 1692 (1991).
C-Y Chen, M. Goto, H. Makino, Y-C Su, E. Tamiya, and I. Karube, Anal. Chim. Acta 265, 5 (1992).
D.J. Claremont, C. Penton, and J.C. Pickup, J. Biomed. Bng. 8, 272 (1986).
D.J. Harrison, R.F.B. Turner, and H.P. Baltes, Anal. Chem. 60, 2002 (1988).
K. Ichimura, J. Polym. Sci., Polym. Chem. Ed. 22, 2817 (1984).
K. Ichimura, K. Mishima, and A. Watanabe, Yosui To Haisui 29(8), 742 (1987).
S. Ikeda, M. Ishida, K. Ito, K. Ichikawa, T. Yukawa, K. Ohkura, A. Nakao, H. Ichihashi, T Kondo, and H. Kojima, The Chem. Soc. Japan 3, 507 (1987).
K. Ishihara, R. Aragaki, T. Ueda, A. Watanabe, and M. Nakabayashi, J.J. Biomed. Mater. Res. 24, 1069 (1990b).
K. Ishihara, T. Ueda, and N. Nakabayashi, Polym. J. 22, 355 (1990a).
I. Kanai and M. Kanai, Clinical Laboratory Methods and Diagnosis (Kobunsha Publishing Co. Seoul, Korea, 1983).
D. Keilin and E.F. Hartree, Biochem. J. 50,331 (1952).
G.F. Khan, Electroanalysis 9, 325 (1997).
K. Kottke-Marchant, J.M. Anderson, Y. Umemura, and R.E. Merchant, Biomaterials 10, 141 (1989).
R. Krishnan, P. Atanasov, and E. Wilkins, Biosensors and Bioelectronics 11, 811 (1996).
E.W. Kristensen, W.G. Kuhr, and R.M. Whightman, Anal. Chem. 59, 1752 (1987).
W. Lager, I. V-Lucadou, H. Nischik, T. Nowak, W. Preidel, L. Ruprecht, M.J. Stanzel, and V. Tegeder, Hormone and Metabolic Research 26, 526 (1994).
T.J. Lenk, B.D. Ratner, R.M. Gendreau, and K.K. Chittur, J. Biomed. Mater. Res. 23, 549 (1989).
C.C. Liu, F.M. Fryburg, and A.K. Chen, Bioelectrochem. Bioenerg. 8, 703 (1981).
H. Liu, Y. Liu, J. Qian, T. Yu, and J. Deng, Microchemical Journal 53, 241 (1996a).
H. Liu, J. Qian, Y. Liu, T. Yu, and J. Deng, Bioelectrochemistry and Bioenergetics 39, 303 (1996b).
H. Liu and J. Deng, Biosensors and Bioelectronics 11, 103 (1996c).
Y. Liu, H. Liu, J. Qian, J. Deng, and T. Yu, Journal of Chemical Technology and Biotechnology 64, 269 (1995).
J. Losada, I. Cuadrado, M. Moran, C.M. Casado, B. Alonso, and M. Barranco, Analytica Chimica Acta 338, 191 (1997).
B. Maruo and N. Tamiya, Enzyme Handbook (Asakura Publishing Co., Tokyo, Japan, 1982).
K. Matsumoto, H. Mizuguchi, and K. Ichimura, Kobunshi Ronbunshu 41(4), 221 (1984).
S. Murabayashi, H. Kambic, H. Harasaki, T. Morimoto, R. Yozu, and Y. Nose, Trans. Am. Soc. Artif. Intern. Organs 31, 50 (1985).
R. Nagata, K. Yokohama, H. Durliat, M. Comtat, S.A. Clark, and I. Karube, Electroanalysis 7, 1027 (1995a).
R. Nagata, K. Yokohama, S.A. Clark, and I. Karube, Biosensors and Bioelectronics 10, 261 (1995b).
K. Nishida, M. Sakakida, K. Ichinose, S. Shimoda, Y. Konno, T. Uemura, M. Uehara, M. Shichiri, K. Ishihara, and N. Nakabayashi, Japanese Journal of Artificial Organs 25, 144 (1996).
L. Olsson, C.F. Mandenius, and J. Volc, Analytical Chemistry 62, 2688 (1990).
D.D. Perrin and B. Dempsey, Buffers for pH and Metal ion Control (Kodansha Publishing Co., Tokyo, Japan, 1981).
S.F. Peteu, D. Emerson, and R.M. Worden, Biosensors and Bioelectronics 11, 1059 (1996).
M.R. Phelps, J.B. Hobbs, D.G. Kilburn, and R.F.B. Turner, Biotechnology and Bioengineering 46, 514 (1995).
I. Queinnec, C. Destruhaut, J.B. Pourciel, and G. Goma, World Journal of Microbiology and biotechnology 8, 7 (1992).
C. Ritter, H. Kontschieder, A. Dolezal, and H. Marsoner, J. Scandinavian Journal of Clinical and Laboratory Investigation 56, 129 (1996).
M. Sakakida, K. Nishida, K. Ichinose, Y. Konno, S. Shimoda, T. Uemura, M. Uehara, M. Shichiri, K. Ishihara, and N. Nakabayashi, Japanese Journal of Artificial Organs 25, 139 (1996).
G. Spanner and R. Niessner, Gresenius' Journal of Analytical Chemistry 335, 327 (1996a).
G. Spanner and R. Niessner, Gresenius' Journal of Analytical Chemistry 354, 306 (1996b).
R. Steinkuhl, C. Dumschat, C. Sundermeier, H. Hinkers, R. Renneberg, K. Cammann, and M. Knoll, Biosensors and Bioelectronics 11, 187 (1996).
S.K. Stephens, I.E. Tothill, P.J. Warner, and A.P.F. Turner, Water Research 31, 41 (1997).
V. Thome-Duret, M.N. Gangnerau, Y. Zhang, G.S. Wilson, and G. Reach, Diabetes and Metabolism 22, 174 (1996).
T. Ueda, K. Ishihara, and N. Nakabayashi, Kobunshi Ronbunshu 48(1), 289 (1991).
P.J.H.J. Van-Os, A. Bult, and W.P. Van-Bennekom, Analytica Chimica Acta 305, 18 (1995).
M.S. Vreeke and P. Rocca, Electroanalysis 8, 55 (1996).
L. Vroman and E.F. Leonard, eds., Ann. N.Y. Acad. Sci. 283, 65 (1977).
D. Wilke, H. Mueller, and N. Kolytsheva, Fresenius' Journal of Analytical Chemistry 357, 534 (1997).
A. Yamasaki, C. Kim, M. Morishita, Y. Tajima, and S. Gondo, Biosensors and Bioelectronics 11, 823 (1996).
N. Yui, K. Kataoka, Y. Sakurai, T. Aoki, K. Sanui, and N. Ogata, Biomaterials 9, 225 (1989).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Chen, CY., Ishihara, K., Nakabayashi, N. et al. Multifunctional Biocompatible Membrane and Its Application to Fabricate A Miniaturized Glucose Sensor with Potential for Use In Vivo. Biomedical Microdevices 1, 155–166 (1999). https://doi.org/10.1023/A:1009952625595
Issue Date:
DOI: https://doi.org/10.1023/A:1009952625595