Abstract
Titanium and its alloys have become increasingly important in the dental and orthopedic fields due to its good machinability, high yield strength, good ductility, excellent corrosion resistance, and superior biocompatibility compared to other materials. However, an inherent drawback of using pure titanium and its alloys as implant material is the significant mismatch between the moduli of bone and titanium, resulting in the stress shielding effect, fibrous tissue ingrowth, and bone resorption, and therefore reducing the lifespan of the implant. Porous titanium is thus a suitable candidate as implant material due to its ability to be manufactured to a specific Young’s modulus—typically that of bone. Porous titanium has the unique advantage of allowing bone tissue ingrowth into the open space of the implants, thereby accelerating the osseointegration process. The human body as well as the oral cavity is a highly complex environment in which the simultaneous interaction between wear and corrosion, namely tribocorrosion, takes place. Thus, understanding these interactions is of great interest in order to characterize the degradation mechanisms of porous titanium materials used as implants. This paper reviews the state-of-the-art of porous titanium as a viable biomedical implant material. A significant part of this paper is focused on how porous titanium is manufactured and how its parameters are controlled. The following sections focus on the corrosion, wear, and tribocorrosion aspects of porous titanium implant materials. Finally, this review also determines the current limitations in the field and provides future directions in this field.
Similar content being viewed by others
References
Toptan F, Alves A, Pinto A, Ponthiaux P (2017) Tribocorrosion behavior of bio-functionalized highly porous titanium. J Mech Behav Biomed Mater 69:144–152
Guo Y, Georgarakis K, Yokoyama Y, Yavari A (2013) On the mechanical properties of TiNb based alloys. J Alloys Compd 571:25–30
Chen X-B, Li Y-C, Du Plessis J, Hodgson PD, Wen C (2009) Influence of calcium ion deposition on apatite-inducing ability of porous titanium for biomedical applications. Acta Biomater 5(5):1808–1820
Krishna BV, Bose S, Bandyopadhyay A (2007) Low stiffness porous Ti structures for load-bearing implants. Acta Biomater 3(6):997–1006
Fretwurst T, Nelson K, Tarnow D, Wang H-L, Giannobile W (2018) Is metal particle release associated with peri-implant bone destruction? An emerging concept. J Dent Res 97(3):259–265
Stergioudi F, Vogiatzis C, Pavlidou E, Skolianos S, Michailidis N (2016) Corrosion resistance of porous NiTi biomedical alloy in simulated body fluids. Smart Mater Struct 25(9):095024
Menini R, Dion M-J, So SK, Gauthier M, Lefebvre L-P (2006) Surface and corrosion electrochemical characterization of titanium foams for implant applications. J Electrochem Soc 153(1):B13–B21
Derks J, Tomasi C (2015) Peri-implant health and disease. A systematic review of current epidemiology. J Clin Periodontol 42:S158–S171
Schwarz F, Derks J, Monje A, Wang HL (2018) Peri-implantitis. J Clin Periodontol 45:S246–S266
Huiskes R, Weinans H, Van Rietbergen B (1992) The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthopaed Relat Res 274:124–134
Geetha M, Singh AK, Asokamani R, Gogia AK (2009) Ti based biomaterials, the ultimate choice for orthopaedic implants—a review. Prog Mater Sci 54(3):397–425
Wen C, Mabuchi M, Yamada Y, Shimojima K, Chino Y, Asahina T (2001) Processing of biocompatible porous Ti and Mg. Scripta Mater 45(10):1147–1153
Wen C, Yamada Y, Shimojima K, Chino Y, Hosokawa H, Mabuchi M (2002) Novel titanium foam for bone tissue engineering. J Mater Res 17(10):2633–2639
Martins JRS Jr, Grandini CR (2014) The influence of heat treatment on the structure and microstructure of Ti-15Mo-xNb system alloys for biomedical applications. Materials Science Forum. https://doi.org/10.4028/www.scientific.net/MSF.783-786.1255
Correa DRN, Kuroda PAB, Grandini CR (2014) Structure, microstructure, and selected mechanical properties of Ti-Zr-Mo alloys for biomedical applications. Adv Mater Res 992:75–80
Gosavi S, Gosavi S, Alla R (2013) Titanium: a miracle metal in dentistry. Trends Biomater Artif Organs 27(1):42–46
Hu X, Shen H, Shuai K, Zhang E, Bai Y, Cheng Y, **ong X, Wang S, Fang J, Wei S (2011) Surface bioactivity modification of titanium by CO2 plasma treatment and induction of hydroxyapatite: in vitro and in vivo studies. Appl Surf Sci 257(6):1813–1823
Landolt D, Mischler S, Stemp M, Barril S (2004) Third body effects and material fluxes in tribocorrosion systems involving a sliding contact. Wear 256(5):517–524
Marino CE, Mascaro LH (2004) EIS characterization of a Ti-dental implant in artificial saliva media: dissolution process of the oxide barrier. J Electroanal Chem 568:115–120
Teixeira M, Alves A, Silva FS, Pinto A, Toptan F (2015) Microstructural characterization of biofunctionalized titanium foams. Microsc Microanal 21(S5):55–56
Alves A, Oliveira F, Wenger F, Ponthiaux P, Celis J-P, Rocha L (2013) Tribocorrosion behaviour of anodic treated titanium surfaces intended for dental implants. J Phys D 46(40):404001
Fan X, Feng B, Weng J, Wang J, Lu X (2011) Processing and properties of porous titanium with high porosity coated by bioactive titania nanotubes. Mater Lett 65(19–20):2899–2901
Asri R, Harun W, Samykano M, Lah N, Ghani S, Tarlochan F, Raza M (2017) Corrosion and surface modification on biocompatible metals: a review. Mater Sci Eng C 77:1261–1274
Disegi J, Eschbach L (2000) Stainless steel in bone surgery. Injury 31:D2–D6
Hosseinalipour S, Ershad-Langroudi A, Hayati AN, Nabizade-Haghighi A (2010) Characterization of sol–gel coated 316L stainless steel for biomedical applications. Prog Org Coat 67(4):371–374
Calin M, Gebert A, Ghinea AC, Gostin PF, Abdi S, Mickel C, Eckert J (2013) Designing biocompatible Ti-based metallic glasses for implant applications. Mater Sci Eng C 33(2):875–883
Faeda RS, Tavares HS, Sartori R, Guastaldi AC, Marcantonio E Jr (2009) Evaluation of titanium implants with surface modification by laser beam: biomechanical study in rabbit tibias. Braz Oral Res 23(2):137–143
Liu J, Wang X, Wu B, Zhang T, Leng Y, Huang N (2013) Tribocorrosion behavior of DLC-coated CoCrMo alloy in simulated biological environment. Vacuum 92:39–43
Hedberg YS, Qian B, Shen Z, Virtanen S, Wallinder IO (2014) In vitro biocompatibility of CoCrMo dental alloys fabricated by selective laser melting. Dent Mater 30(5):525–534
Shadanbaz S, Dias GJ (2012) Calcium phosphate coatings on magnesium alloys for biomedical applications: a review. Acta Biomater 8(1):20–30
Dorozhkin SV (2014) Calcium orthophosphate coatings on magnesium and its biodegradable alloys. Acta Biomater 10(7):2919–2934
** W, Wang G, Lin Z, Feng H, Li W, Peng X, Qasim AM, Chu PK (2017) Corrosion resistance and cytocompatibility of tantalum-surface-functionalized biomedical ZK60 Mg alloy. Corros Sci 114:45–56
Gray J, Luan B (2002) Protective coatings on magnesium and its alloys—a critical review. J Alloys Compd 336(1–2):88–113
Hornberger H, Virtanen S, Boccaccini A (2012) Biomedical coatings on magnesium alloys—a review. Acta Biomater 8(7):2442–2455
Barrabés M, Sevilla P, Planell J, Gil F (2008) Mechanical properties of nickel–titanium foams for reconstructive orthopaedics. Mater Sci Eng C 28(1):23–27
Gepreel MA-H, Niinomi M (2013) Biocompatibility of Ti-alloys for long-term implantation. J Mech Behav Biomed Mater 20:407–415
Davidson J, Mishra A, Kovacs P, Poggie R (1994) New surface-hardened, low-modulus, corrosion-resistant Ti-13Nb-13Zr alloy for total hip arthroplasty. Bio-med Mater Eng 4(3):231–243
Kuroda D, Niinomi M, Morinaga M, Kato Y, Yashiro T (1998) Design and mechanical properties of new β type titanium alloys for implant materials. Mater Sci Eng A 243(1–2):244–249
Steinemann S, Winter G, Leray J (1980) Evaluation of biomaterials. Willey, New York, pp 5435–5438
Yavari SA, Ahmadi S, van der Stok J, Wauthlé R, Riemslag A, Janssen M, Schrooten J, Weinans H, Zadpoor AA (2014) Effects of bio-functionalizing surface treatments on the mechanical behavior of open porous titanium biomaterials. J Mech Behav Biomed Mater 36:109–119
Liu YJ, Li SJ, Wang HL, Hou WT, Hao YL, Yang R, Sercombe TB, Zhang LC (2016) Microstructure, defects and mechanical behavior of beta-type titanium porous structures manufactured by electron beam melting and selective laser melting. Acta Mater 113:56–67
Torres Y, Trueba P, Pavón J, Montealegre I, Rodríguez-Ortiz J (2014) Designing, processing and characterisation of titanium cylinders with graded porosity: an alternative to stress-shielding solutions. Mater Des 63:316–324
Traini T, Mangano C, Sammons R, Mangano F, Macchi A, Piattelli A (2008) Direct laser metal sintering as a new approach to fabrication of an isoelastic functionally graded material for manufacture of porous titanium dental implants. Dent Mater 24(11):1525–1533
Dunand DC (2004) Processing of titanium foams. Adv Eng Mater 6(6):369–376
Cirincione R, Anderson R, Zhou J, Mumm D, Soboyejo WO (2002) An investigation of the effects of sintering duration and powder sizes of the porosity and compression strength of porous Ti-6Al-4V. Processing and properties of lightweight cellular metals and structures. p 189
Schuh C, Noel P, Dunand D (2000) Enhanced densification of metal powders by transformation-mismatch plasticity. Acta Mater 48(8):1639–1653
Taylor N, Dunand D, Mortensen A (1993) Initial stage hot pressing of monosized Ti and 90% Ti-10% TiC powders. Acta Metall Mater 41(3):955–965
Oh I-H, Nomura N, Hanada S (2002) Microstructures and mechanical properties of porous titanium compacts prepared by powder sintering. Mater Trans 43(3):443–446
Oh I-H, Nomura N, Masahashi N, Hanada S (2003) Mechanical properties of porous titanium compacts prepared by powder sintering. Scripta Mater 49(12):1197–1202
Oh I-H, Segawa H, Nomura N, Hanada S (2003) Microstructures and mechanical properties of porosity-graded pure titanium compacts. Mater Trans 44(4):657–660
Riccent R, Matteazzi P (2001) Porous nanocrystalline Ti-alloy implants. Int J Powder Metall 37(4):61–66
Asaoka K, Kon M (2003) Sintered porous titanium and titanium alloys as advanced biomaterials. Mater Sci Forum 426:3079–3084
Thieme M, Wieters K-P, Bergner F, Scharnweber D, Worch H, Ndop J, Kim T, Grill W (2001) Titanium powder sintering for preparation of a porous functionally graded material destined for orthopaedic implants. J Mater Sci: Mater Med 12(3):225–231
Murray G, Semple JC (1981) Transfer of tensile loads from a prosthesis to bone using porous titanium. J Bone Joint Surg Br 63(1):138–141
Sypeck DJ, Parrish PA, Wadley HN (1998) Novel hollow powder porous structures. MRS Online Proc Libr Arch. https://doi.org/10.1557/PROC-521-205
Jee C, Guo Z, Evans J, Özgüven N (2000) Preparation of high porosity metal foams. Metall Mater Trans B 31(6):1345–1352
Hurysz K, Clark J, Nagel A, Hardwicke C, Lee K, Cochran J, Sanders T (1998) Steel and titanium hollow sphere foams. MRS Online Proc Libr Arch. https://doi.org/10.1557/PROC-521-191
Aşık EE, Bor Ş (2015) Fatigue behavior of Ti–6Al–4V foams processed by magnesium space holder technique. Mater Sci Eng A 621:157–165
Wheeler K, Karagianes M, Sump K (1983) Porous titanium alloy for prosthesis attachment. In: Titanium alloys in surgical implants. ASTM International, Phoenix
Kostornov A, Galstyan L, Mnatsakanyan S, Agayan S (1986) The physicomechanical properties of porous titanium base powder materials. Sov Powder Metall Met Ceram 25(11):909–911
Kostornov A, Agayan S (1990) Determining the quality of baking of porous titanium to porosity-free. Sov Powder Metall Met Ceram 29(10):804–807
Bram M, Stiller C, Buchkremer HP, Stöver D, Baur H (2000) High-porosity titanium, stainless steel, and superalloy parts. Adv Eng Mater 2(4):196–199
Rausch G, Banhart JE, Degischer H (2002) Handbook of cellular metals. Wiley, Weinheim
Zhao X, Sun H, Lan L, Huang J, Zhang H, Wang Y (2009) Pore structures of high-porosity NiTi alloys made from elemental powders with NaCl temporary space-holders. Mater Lett 63(28):2402–2404
Jakubowicz J, Adamek G, Pałka K, Andrzejewski D (2015) Micro-CT analysis and mechanical properties of Ti spherical and polyhedral void composites made with saccharose as a space holder material. Mater Charact 100:13–20
Andersen O, Waag U, Schneider L, Stephani G, Kieback B (2000) Novel metallic hollow sphere structures. Adv Eng Mater 2(4):192–195
Kupp D, Claar D, Flemmig K, Waag U, Goehler H (2002) Processing of controlled porosity titanium-based materials. Adv Powder Metall Part Mater (2):2–126
Li JP, Li SH, De Groot K, Layrolle P (2002)Preparation and characterization of porous titanium. Key Eng Mater. https://doi.org/10.4028/www.scientific.net/KEM.218-220.51
Li JP, Li SH, De Groot K, Layrolle P (2003) Improvement of porous titanium with thicker struts. Key Eng Mater. https://doi.org/10.4028/www.scientific.net/KEM.240-242.547
Kearns M, Blenkinsop P (1987) Manufacture of a novel porous metal. Met Mater 3(2):85–88
Dunand D, Teisen J (1998) Superplastic foaming of titanium and Ti-6Al-4V. MRS Online Proc Libr Arch. https://doi.org/10.1557/PROC-521-231521
Davis N, Teisen J, Schuh C, Dunand D (2001) Solid-state foaming of titanium by superplastic expansion of argon-filled pores. J Mater Res 16(5):1508–1519
Parthasarathy J, Starly B, Raman S, Christensen A (2010) Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM). J Mech Behav Biomed Mater 3(3):249–259
Heinl P, Müller L, Körner C, Singer RF, Müller FA (2008) Cellular Ti–6Al–4V structures with interconnected macro porosity for bone implants fabricated by selective electron beam melting. Acta Biomater 4(5):1536–1544
Revathi A, Borrás AD, Muñoz AI, Richard C, Manivasagam G (2017) Degradation mechanisms and future challenges of titanium and its alloys for dental implant applications in oral environment. Mater Sci Eng C 76:1354–1368
Seah K, Thampuran R, Teoh S (1998) The influence of pore morphology on corrosion. Corros Sci 40(4–5):547–556
Fojt J, Joska L, Málek J (2013) Corrosion behaviour of porous Ti–39Nb alloy for biomedical applications. Corros Sci 71:78–83
Alves A, Sendão I, Ariza E, Toptan F, Ponthiaux P, Pinto A (2016) Corrosion behaviour of porous Ti intended for biomedical applications. J Porous Mater 23(5):1261–1268
Li Y-H, Rao G-B, Rong L-J, Li Y-Y, Ke W (2003) Effect of pores on corrosion characteristics of porous NiTi alloy in simulated body fluid. Mater Sci Eng A 363(1–2):356–359
Long M, Rack H (1998) Titanium alloys in total joint replacement—a materials science perspective. Biomaterials 19(18):1621–1639
Wu S, Liu X, Wu G, Yeung KW, Zheng D, Chung CY, Xu Z, Chu PK (2013) Wear mechanism and tribological characteristics of porous NiTi shape memory alloy for bone scaffold. J Biomed Mater Res A 101(9):2586–2601
Salahinejad E, Amini R, Marasi M, Hadianfard M (2010) Microstructure and wear behavior of a porous nanocrystalline nickel-free austenitic stainless steel developed by powder metallurgy. Mater Des 31(4):2259–2263
Liu Z, Ji F, Wang M, Zhu T (2017) Study on the tribological properties of porous titanium sliding against tungsten carbide YG6. Metals 7(1):28
Prabu SS, Prathiba S, Venkatesan N, Sharma A, Ahmed S, Shah YA (2014) Influence of Titanium on dry sliding wear behaviour of sintered P/M low alloy steel (Fe-CW). Proced Eng 97:2110–2118
Licausi M-P, Muñoz AI, Borrás VA (2013) Tribocorrosion mechanisms of Ti6Al4V biomedical alloys in artificial saliva with different pHs. J Phys D 46(40):404003
Mathew MT, Barão VA, Yuan JC-C, Assunção WG, Sukotjo C, Wimmer MA (2012) What is the role of lipopolysaccharide on the tribocorrosive behavior of titanium? J Mech Behav Biomed Mater 8:71–85
Doni Z, Alves A, Toptan F, Gomes J, Ramalho A, Buciumeanu M, Palaghian L, Silva F (2013) Dry sliding and tribocorrosion behaviour of hot pressed CoCrMo biomedical alloy as compared with the cast CoCrMo and Ti6Al4V alloys. Mater Des (1980–2015) 52:47–57
Licausi M-P, Muñoz AI, Borrás VA (2013) Influence of the fabrication process and fluoride content on the tribocorrosion behaviour of Ti6Al4V biomedical alloy in artificial saliva. J Mech Behav Biomed Mater 20:137–148
Dimah MK, Albeza FD, Borrás VA, Muñoz AI (2012) Study of the biotribocorrosion behaviour of titanium biomedical alloys in simulated body fluids by electrochemical techniques. Wear 294:409–418
Diomidis N, Mischler S, More N, Roy M (2012) Tribo-electrochemical characterization of metallic biomaterials for total joint replacement. Acta Biomater 8(2):852–859
Mathew MT, Abbey S, Hallab NJ, Hall DJ, Sukotjo C, Wimmer MA (2012) Influence of pH on the tribocorrosion behavior of CpTi in the oral environment: synergistic interactions of wear and corrosion. J Biomed Mater Res B 100(6):1662–1671
Souza JCM, Barbosa SL, Ariza E, Celis JP, Rocha LA (2012) Simultaneous degradation by corrosion and wear of titanium in artificial saliva containing fluorides. Wear 292:82–88
Cvijović-Alagić I, Cvijović Z, Mitrović S, Panić V, Rakin M (2011) Wear and corrosion behaviour of Ti–13Nb–13Zr and Ti–6Al–4V alloys in simulated physiological solution. Corros Sci 53(2):796–808
Majumdar P, Singh S, Chakraborty M (2011) The influence of heat treatment and role of boron on sliding wear behaviour of β-type Ti–35Nb–7.2 Zr–5.7 Ta alloy in dry condition and in simulated body fluids. J Mech Behav Biomed Mater 4(3):284–297
Majumdar P, Singh S, Chakraborty M (2010) Wear properties of Ti–13Zr–13Nb (wt.%) near β titanium alloy containing 0.5 wt.% boron in dry condition, Hank’s solution and bovine serum. Mater Sci Eng C 30(7):1065–1075
Majumdar P, Singh S, Chakraborty M (2008) Wear response of heat-treated Ti–13Zr–13Nb alloy in dry condition and simulated body fluid. Wear 264(11–12):1015–1025
Komotori J, Hisamori N, Ohmori Y (2007) The corrosion/wear mechanisms of Ti–6Al–4V alloy for different scratching rates. Wear 263(1–6):412–418
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Manoj, A., Kasar, A.K. & Menezes, P.L. Tribocorrosion of Porous Titanium Used in Biomedical Applications. J Bio Tribo Corros 5, 3 (2019). https://doi.org/10.1007/s40735-018-0194-4
Received:
Revised:
Accepted:
Published: