Abstract
Purpose
To assess the efficacy of Herbert cannulated bone screw versus Lag screw in fixation of oblique mandibular fractures.
Materials and Method
Study composed of two groups of 20 patients each and descriptive statistics were performed with p value set at 0.05 with confidence interval of 95%. Group A was treated by Titanium Lag screws; while, Group B was treated by Titanium Herbert Cannulated Bone Screws for the management of oblique mandibular fractures. Postoperatively, all the patients were evaluated clinically and radiographically by recording the incidence of complications (if any) which included trismus, neurosensory deficit, swelling, infection. Parameters such as occlusal discrepancy, rigid fixation (interfragmentary gap) and duration of surgery were also recorded for all the patients.
Results
All the patients were followed for a period of three months. Difference in mouth opening was found to be statistically significant during 1st month follow-up (p-Value-0.002). Postoperatively, the mean interfragmentary gap in Group A was significantly more than Group B (p-Value-0.000). Other parameters like neurosensory deficits, occlusal discrepancies, chewing efficiency, stability of fractured fragments and post-operative complications in terms of swelling, hardware exposure, radiolucency surrounding screw and wound dehiscence did not show any statistically significant difference.
Conclusion
The obtained results showed that both lag screws and Herbert cannulated bone screws fulfill the treatment goals of adequate reduction, fixation and stabilization of oblique mandibular fractures. Herbert screws have shown to have better results in terms of interfragmentary gap reduction as compared to lag screws.
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs12663-023-02095-z/MediaObjects/12663_2023_2095_Fig1_HTML.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs12663-023-02095-z/MediaObjects/12663_2023_2095_Fig2_HTML.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs12663-023-02095-z/MediaObjects/12663_2023_2095_Fig3_HTML.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs12663-023-02095-z/MediaObjects/12663_2023_2095_Fig4_HTML.png)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs12663-023-02095-z/MediaObjects/12663_2023_2095_Fig5_HTML.png)
Similar content being viewed by others
References
Natu SS et al (2012) An epidemiological study on pattern and incidence of mandibular fractures. Plast Surg Int 2012:834364. https://doi.org/10.1155/2012/834364
Yuen HW, Hohman MH, Mazzoni T. Mandible Fracture (2023) In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2023 Jan. Available from: https://www.ncbi.nlm.nih.gov/books/NBK507705/
Balasubramanian S, Kumaravelu C, Elavenil P, Krishnakumar Raja VB (2014) Solitary lag-screw fixation for mandibular angle fractures: Prospective study. SRM J Res Dent Sci 5:180–185
El-Mahallawy Y, El-Ghamrawey S, Khalil M (2018) The use of Herbert cannulated bone screw in the treatment of mandibular fractures (a clinical and radiographic study). Alex Dent J 43(2):19–25. https://doi.org/10.21608/Adjalexu.2018.57618
Uppada UK, Sinha R, Tiwari P, Vennela S, Khan TA (2019) Evaluation of efficacy of various fixation devices in management of anterior mandibular fractures: a prospective clinical study. J Dent Res Rev 6:72–76
Ellis E 3rd, Ghali GE (1991) Lag screw fixation of anterior mandibular fractures. J Oral Maxillofac Surg 49(1):13–21. https://doi.org/10.1016/0278-2391(91)90259-o
Bansal P, Kumar S, Mishra V, Jaiswal Y, Das G (2017) Evaluation of titanium lag screw osteosynthesis in the management of mandibular fractures. World J Dent 8(4):315–320
Herbert TJ, Fisher WE (1984) Management of the fractured scaphoid using a new bone screw. J Bone Joint Surg Br 66(1):114–123. https://doi.org/10.1302/0301-620X.66B1.6693468
Vineeth K, Lalitha RM, Prasad K, Ranganath K, Shwetha V, Singh J (2013) A comparative evaluation between single noncompression titanium miniplate and three dimensional titanium miniplate in treatment of mandibular angle fracture—a randomized prospective study. J Craniomaxillofac Surg 41(2):103–109. https://doi.org/10.1016/j.jcms.2012.05.015
Agnihotri A, Prabhu S, Thomas S (2014) A comparative analysis of the efficacy of cortical screws as lag screws and miniplates for internal fixation of mandibular symphyseal region fractures: a randomized prospective study. Int J Oral Maxillofac Surg 43(1):22–28. https://doi.org/10.1016/j.ijom.2013.07.001
Gokkulakrishnan S, Singh S, Sharma A, Shahi AK (2012) An analysis of postoperative complications and efficacy of 3-D miniplates in fixation of mandibular fractures. Dent Res J (Isfahan) 9(4):414–421
Ellis E 3rd (2012) Is lag screw fixation superior to plate fixation to treat fractures of the mandibular symphysis? J Oral Maxillofac Surg 70(4):875–882. https://doi.org/10.1016/j.joms.2011.08.042
Goyal M, Jhamb A, Chawla S, Marya K, Dua JS, Yadav S (2012) A comparative evaluation of fixation techniques in anterior mandibular fractures using 2.0 mm monocortical titanium miniplates versus 2.4 mm cortical titanium lag screws. J Maxillofac Oral Surg. 11(4):442–50. https://doi.org/10.1007/s12663-012-0342-1
Kotrashetti SM, Singh AG (2017) Prospective study of treatment outcomes with lag screw versus Herbert screw fixation in mandibular fractures. Int J Oral Maxillofac Surg 46(1):54–58. https://doi.org/10.1016/j.ijom.2016.08.006
El-Mahallawy Y, Al-Mahalawy H (2018) Herbert cannulated bone screw osteosynthesis in anterior mandibular fracture treatment: a comparative study with lag screw and miniplate. J Oral Maxillofac Surg 76(6):1281.e1-1281.e8. https://doi.org/10.1016/j.joms.2018.01.034
Ram R, Ahsan R, Bhardwaj Y, Ghezta N, Kumar S (2017) Assessment of fixation of mandibular interforaminal fractures by using a single second-generation headless compression screw: a pilot study. Craniomaxillofac Trauma Reconstr 10(2):138–144. https://doi.org/10.1055/s-0036-1594276
Ranvijay SAK, Singh M (2017) Comparative study of the efficacy of titanium lag screw and titanium miniplates for internal fixation of anterior mandibular fractures. Int J Sci Stud 5(2):29–35
Funding
This study has received no financial support.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
No conflict of interest.
Ethical Approval
The study involves human participants and is approved by the institutional ethical committee, Teerthanker Mahaveer Dental College & Research Institute, Teerthanker Mahaveer University, Moradabad, U.P, India.
Informed Consent
A duly signed informed consent in a language understood to the patient was taken by all the patients before including them in the study.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Johari, S., Gupta, D.S., Khare, G. et al. Evaluation of Efficacy of Herbert Bone Screw and Lag Screw in Management of Oblique Mandibular Fractures: A Prospective Randomized Comparative Study. J. Maxillofac. Oral Surg. 23, 488–496 (2024). https://doi.org/10.1007/s12663-023-02095-z
Received:
Accepted:
Published:
Issue Date: