Change in Efficiency of Flow Path of Modernized and Non-Modernized Turbines Having a Capacity of 300 MW During Operation

  • Published:
Power Technology and Engineering Aims and scope

The results of changes in the thermal efficiency of high-pressure cylinders (HPC) of active and reactive types, as well as intermediate-pressure cylinders (IPC) with stages of an improved design of turbines with a capacity of 300 MW produced by LMZ during long-term operation are presented on the example of Konakovskaya regional hydroelectric power plant (GRES). Recommendations are made regarding the possible use of the proposed technical solutions in power plants with similar turbines.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. A. G. Kostyuk and A. D. Trukhny, “Comparison of active and reactive high-pressure cylinders of steam turbines,” Teploénergetika, No. 6, 2 – 13 (2005).

  2. G. D. Avrutsky, M. V. Lazarev, I. A. Savenkova, M. V. Lazareva, L. L. Simoyu, A. V. Melnikov, and V. D. Gaev, “Reconstruction of 300 MW power units of Konakovskaya GRES,” Élektr. Stantsii, No. 8, 29 – 33 (2012).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. V. Lazarev.

Additional information

Translated from Élektricheskie Stantsii, No. 2, February 2022, pp. 1 – 6. https://doi.org/10.34831/EP.2022.1087.2.001

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lazarev, M.V., Zakharov, A.E., Filatov, K.V. et al. Change in Efficiency of Flow Path of Modernized and Non-Modernized Turbines Having a Capacity of 300 MW During Operation. Power Technol Eng 56, 261–264 (2022). https://doi.org/10.1007/s10749-023-01504-0

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10749-023-01504-0

Keywords

Navigation