Abstract
Background
There are limited studies focusing on hemodynamic changes between elective and emergent C/S cases. We considered that a better understanding of the alterations and physiological reactions in both situations with non-invasive novel technologies might be useful in managing maternal and fetal sides.
Methods
In this prospective observational study, non-invasive hemodynamic changes were observed by using the whole-body impedance method using the NICaS™ device. CO, cardiac index (CI), stroke volume (SV), stroke index (SI), total peripheric resistance (TPR), and cardiac reserve (GGI) parameters were evaluated with a non-invasive method. Measurements were done initiating before surgery, 9 times of 5 min intervals.
Results
All 95 patients finished the study. 47 cesarean sections were in the elective group, 48 were in the emergent group. SV in 4.5.6. time intervals were statistically increased in the elective group (p values: SvMl4: 0.025, SvMl5: 0.049, SvMl6: 0.044) (p < 0.05). SI in the second-time interval was statistically increased in the emergent group (p-value SI2: 0.047) (p < 0.05). SI in the 4th time interval was statistically increased in the elective group (p-value SI4: 0.047) (p < 0.05). CO measurements were not statistically different between groups in all time intervals for all comparisons. CI in the second time interval was statistically decreased in the elective group (p-value CI2: 0.012) (p < 0.05). GGI in the 4th time interval was statistically increased in the elective group (p-value GGI4: 0.035) (p < 0.05). TPRI in the second time interval was statistically increased in the elective group (p-value TPRI 2: 0.014) (p < 0.05).
Conclusions
Understanding normal hemodynamic values before, during, and after C/S is feasible and might help the clinician assess patients’ cardiac performance with a reliable noninvasive technique. NICaS might be a reliable tool to evaluate patients’ baseline values and diagnose complications earlier during the surgery.
Similar content being viewed by others
References
Lavie A, Ram M, Lev S et al (2018) Maternal hemodynamics in late gestation and immediate postpartum in singletons vs. twin pregnancies. Arch Gynecol Obstet. 297(2):353–363. https://doi.org/10.1007/s00404-017-4601-8
Lavie A, Ram M, Lev S et al (2018) Maternal cardiovascular hemodynamics in normotensive versus preeclamptic pregnancies: a prospective longitudinal study using a noninvasive cardiac system (NICaS™) Lavie et al. BMC Pregnancy Childbirth 18(1):229. https://doi.org/10.1186/s12884-018-1861-7
Hassan-Tash P, Ismail U, Kirkpatrick IDC et al (2023) Correlation of impedance cardiography-derived and cardiac magnetic resonance-derived stroke volumes. Curr Probl Cardiol. 48(2):101457. https://doi.org/10.1016/j.cpcardiol.2022.101457
Cotter G, Schachner A, Sasson L, Dekel H, Moshkovitz Y (2006) Impedance cardiography revisited. Physiol Meas 27(9):817–827. https://doi.org/10.1088/0967-3334/27/9/005
Adıyeke E (2019) Is the emergency cesarean section associated with hypotension? Retrospective analysis of 80 patients undergoing elective or emergency cesarean section under spinal anesthesia. Haydarpasa Numune Med J 59(4):342–346
Yang XJ, Sun SS (2017) Comparison of maternal and fetal complications in elective and emergency cesarean section: a systematic review and meta-analysis. Arch Gynecol Obstet 296(3):503–512. https://doi.org/10.1007/s00404-017-4445-2
Torre-Amione G, Milo O, Kaluski E (2004) Whole-body electrical bio-impedance is accurate in non-invasive determination of cardiac output: a thermodilution controlled, prospective double blind evaluation. J Card Fail 10(4):S38–S39
Paredes OL, Shite J, Shinke T et al (2006) Impedance cardiography for cardiac output estimation: reliability of wrist-to-ankle electrode configuration. Circ J 70(9):1164–1168. https://doi.org/10.1253/circj.70.1164
Tanino Y, Shite J, Paredes OL et al (2009) Whole body bioimpedance monitoring for outpatient chronic heart failure follow up. Circ J 73(6):1074–1079. https://doi.org/10.1253/circj.cj-08-0847
Taniguchi Y, Emoto N, Miyagawa K et al (2013) Noninvasive and simple assessment of cardiac output and pulmonary vascular resistance with whole-body impedance cardiography is useful for monitoring patients with pulmonary hypertension. Circ J 77(9):2383–2389. https://doi.org/10.1253/circj.cj-13-0172
Dennis A, Hardy L (2016) Defining a reference range for vital signs in healthy term pregnant women undergoing caesarean section. Anaesth Intensive Care 44(6):752–757. https://doi.org/10.1177/0310057X1604400619
Cheshire J, Lissauer D, Parry-Smith W, Tobias A, Smith GB, Isaacs R, Hundley V, Modified Obstetric Early Warning Systems (MObs) Research Group (2020) Escalation triggers and expected responses in obstetric early warning systems used in UK consultant-led maternity units. Resuscitation Plus 5:100060. https://doi.org/10.1016/j.resplu.2020.100060
Levin H, LaSala A (2014) Intrapartum obstetric management. Semin Perinatol 38(5):245–251. https://doi.org/10.1053/j.semperi.2014.04.013
Tihtonen K, Kööbi T, Yli-Hankala A, Huhtala H, Uotila J (2006) Maternal haemodynamics in pre-eclampsia compared with normal pregnancy during caesarean delivery. BJOG 113(6):657–663. https://doi.org/10.1111/j.1471-0528.2006.00931.x
Robson SC, Boys RJ, Rodeck C, Morgan B (1992) Maternal and fetal haemodynamic effects of spinal and extradural anaesthesia for elective caesarean section. Br J Anaesth 68(1):54–59. https://doi.org/10.1093/bja/68.1.54
Milsom I, Forssman L, Biber B, Dottori O, Rydgren B, Sivertsson R (1985) Maternal haemodynamic changes during caesarean section: a comparison of epidural and general anaesthesia. Acta Anaesthesiol Scand 29(2):161–167. https://doi.org/10.1111/j.1399-6576.1985.tb02178.x
Ouzounian JG, Elkayam U (2012) Physiologic changes during normal pregnancy and delivery. Cardiol Clin 30(3):317–329. https://doi.org/10.1016/j.ccl.2012.05.004
Ram M, Lavie A, Lev S, Blecher Y, Amikam U, Shulman Y, Avnon T, Weiner E, Many A (2018) Casting doubt on the value of assessing the cardiac index in pregnancy. J Matern Fetal Neonatal Med 31(23):3080–3084. https://doi.org/10.1080/14767058.2017.1364720
Langesaeter E, Rosseland LA, Stubhaug A (2006) Hemodynamic effects of oxytocin during cesarean delivery. Int J Gynaecol Obstet 95(1):46–47. https://doi.org/10.1016/j.ijgo.2006.05.032
Elvedi-Gasparović V, Klepac-Pulanić T, Peter B (2006) Maternal and fetal outcome in elective versus emergency caesarean section in a develo** country. Coll Antropol 30(1):113–118
Darnal N, Dangal G (2020) Maternal and fetal outcome in emergency versus elective caesarean section. J Nepal Health Res Counc. 18(2):186–189. https://doi.org/10.33314/jnhrc.v18i2.2093
Orbach-Zinger S, Razinsky E, Bizman I, Firman S, Gat R, Davis A, Ashwal E, Shmueli A, Vaturi M, Gabbay-Benziv R, Eidelman LA (2019) Perioperative noninvasive cardiac output monitoring in parturients with singleton and twin pregnancies undergoing cesarean section under spinal anesthesia with prophylactic phenylephrine drip: a prospective observational cohort study. J Matern Fetal Neonatal Med 32(23):3980–3985. https://doi.org/10.1080/14767058.2018.148060
Atzmon Y, Ben Ishay E, Hallak M, Littman R, Eisenkraft A, Gabbay-Benziv R (2020) Continuous maternal hemodynamics monitoring at delivery using a novel, noninvasive, wireless, PPG-based sensor. J Clin Med 10(1):8. https://doi.org/10.3390/jcm10010008
Faul F, Erdfelder E, Buchner A et al. (2009) Statistical power analyses using G*Power 3.1: tests for correlation and regression analyses. Behav Res Methods 41(4):1149–1160. https://doi.org/10.3758/BRM.41.4.1149
Funding
The author(s) received no funds, grants, or other financial support for this article's research, authorship, and/or publication.
Author information
Authors and Affiliations
Contributions
All authors contributed to the study conception and design. Material preparation, data collection and analysis were performed by ZÇ, AV and EY. The first draft of the manuscript was written by ZÇ and ÜAT and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Conflict of interest
The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Çavuş, Z., Vahapoğlu, A., Türkmen, Ü.A. et al. Comparing elective and emergency caesarean section by using bioimpedance method. Arch Gynecol Obstet 309, 2633–2641 (2024). https://doi.org/10.1007/s00404-023-07166-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00404-023-07166-7