Abstract
The purpose of this paper is to present the experience with two patients with pseudoarthrosis of mandibular body fractures and unacceptable anesthesia of the lower lip and chin on the affected side. This was corrected by establishing stable fixation with locking screw mandibular plate, microsurgical repair of the inferior alveolar nerve, and filling the fracture gap with an autogeneous bone graft. The combination of these therapies resulted in satisfactory sensory improvement without complications in both patients.
Similar content being viewed by others
Author information
Authors and Affiliations
Additional information
Received: 25 May 1999 / Accepted: 29 September 1999
Rights and permissions
About this article
Cite this article
van der Wal, K., de Visscher, J. Simultaneous treatment of pseudoarthrosis of mandibular body fractures and inferior alveolar nerve defects. E J Plastic Surg 23, 88–90 (2000). https://doi.org/10.1007/s002380050022
Issue Date:
DOI: https://doi.org/10.1007/s002380050022