Log in

An algorithm for calculating fresh air age in central ventilation system

  • Published:
Science in China Series E: Technological Sciences Aims and scope Submit manuscript

Abstract

Fresh air age is an important index to evaluate indoor environment. The conventional method for measuring or calculating fresh air age is only suitable for simple ventilation systems and not for central ventilation systems. In this paper, an algorithm for calculating fresh air age in central ventilation system is presented, which is based on the analysis of air flow in duct and air mixing. An example is given to illustrate the algorithm. The fresh air age in every ventilated room and duct can be acquired after all rooms and duct are directly calculated in turn without iteration. The algorithm is suitable for different central ventilation systems.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Zhu, N., Wang, K. H., Tian, Z., Characteristic analysis of air conditioning systems in sick buildings, HV&AC (in Chinese), 1999, 29(2): 11–15.

    Google Scholar 

  2. Ma, R. M., International development in research of indoor air quality in non-industrial buildings, HV&AC (in Chinese), 1999, 20(2): 38–41.

    Google Scholar 

  3. Li, X. T., Yang, J. R., Wang, X., Status and development of indoor air quality research, HV&AC (in Chinese), 2000, 39(3): 36–40.

    MathSciNet  Google Scholar 

  4. Dorgan, C. E., Productivity link to the indoor environment estimated relative to ASHRAE 62-1989, in Proceedings of Health Buildings’94, Budapest, 1994, 461–472.

  5. ASHRAE STANDARD 62-89: Ventilation for Acceptable Indoor Air Quality, 1989.

  6. David, W. B., Indoor Air Quality and HVAC Systems, Berlin: Lewis Pub., 1993, 12–20.

    Google Scholar 

  7. CIBSE Guide: Installation and Equipment Data, London: CIBSE, 1986.

    Google Scholar 

  8. Sandberg, M., Sjoberg, M., The use of moments for assessing air quality in ventilated rooms, Building and Environment, 1983, 18(4): 181–197.

    Article  Google Scholar 

  9. Li, X. T., Wang, X., Li, X. F. et al. Investigation on air age in a ventilated room with tracer gas technique. HV&AC (in Chinese), 2001, 31(4): 79–81.

    Google Scholar 

  10. Koskela, H. K., Rolin, I. E., Norell, L. O., Comparison between forced displacement and mixing ventilation in a garage, ASHRAE Transactions, IN-91, 18(7): 1119–1126.

  11. Li, X. T., Wang, X., Li, X. F., Investigation on the relationship between flow pattern and air age, in Sixth International IBPSA Conference-Building Simulation ’99, Kyoto, Japan, 1999, 423–429.

  12. Li, X. T., Jiang, Y., Calculating air age in a ventilated room with CFD method, Journal of Tsinghua University (Sci. & Tech.) (in Chinese), 1998, 38(5): 28–31.

    Google Scholar 

  13. Li, X. T., Li, X. F., Zhu, Y. X., The mathematical modeling of air age, in International Symposium on Air Conditioning in High Rise Buildings’97. Sept. 9–12, 1997, Shanghai, 241–246.

  14. Li, X. T., Wang, X., Li, Y. Numerical method for air age calculation in ventilated room. Building Energy & Environment (in Chinese), 1999, 18(1): 2–5.

    Google Scholar 

  15. Yuan, X. X., Chen, Q. Y., Glicksman, L. R., Performance evaluation and development of design guidelines for displacement ventilation, Final Report to ASHRAE TC5.3-Room Air Distribution on ASHRAE Research Project-RP-949.

  16. Yang Jia, Wu **angsheng, The research of the numerical simulation of the age-of-air., in Proceeding of the 4th International Conference on Indoor Air Quality, Ventilation & Energy Conservation in Buildings, Hong Kong: City University of Hong Kong, 2001, 339–345.

  17. Awbi, H. B., Karimipanah, T., A comparison between three methods of low-level air supplies, in Proceeding of the 4th International Conference on Indoor Air Quality, Ventilation & Energy Conservation in Buildings, Hong Kong: City University of Hong Kong, 2001, 311–316.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Li **anting.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Li, X., Li, D. & Dou, C. An algorithm for calculating fresh air age in central ventilation system. Sci. China Ser. E-Technol. Sci. 46, 182–190 (2003). https://doi.org/10.1007/BF03039577

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03039577

Keywords

Navigation